Dacor RV30X Installationsanleitung

Seite von 12

Verifying the Package Contents
• Use and Care Manual
• Anchoring Legs
Installation Planning
A qualified technician must complete the 
installation of this appliance. Proper installation 
is your responsibility.
Raised Vent System Specifications
Raised Vent 
Model No.
For Use with
For Use with Blower
Duct Size
RV30
30” Cooktops
CABP3, REMP3/16
3 1/4”x10”, 8” & 10”
RV36
36” Cooktops
CABP3, REMP3/16
3 1/4”x10”, 8” & 10”
RV46
46” Cooktops
CABP3, REMP3/16
3 1/4”x10”, 8” & 10”
For detailed information on the remote blowers, refer to the Remote Blowers Installation Instructions.
wARNINg: 
Failure to disconnect power may 
result in electrical shock or fire 
hazard! If the electric service 
provided does not meet the 
product specifications, do not 
proceed with the installation. Call 
the selling dealer or a licensed 
electrician.
Electrical Power Supply 
Requirements
It is the owner’s responsibility to ensure that 
the electrical connection of this appliance 
is performed by a qualified electrician. The 
electrical installation, including minimum supply 
wire size and grounding, must be in accordance 
with the National Electric code ANSI/NFPA 70-
2002* (or latest revision) and local codes and 
ordinances. 
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct 120VAC, 60Hz, 15A circuit must 
be supplied for this appliance from a separate, 
grounded, circuit that is protected by a properly 
sized circuit breaker or time delay fuse.
Duct Planning
wARNINgS
1.  To reduce the risk of fire and 
to properly exhaust air, ducted 
fans must be vented to outside. 
Do not vent exhaust air into 
spaces within walls, ceilings, 
attics, crawl spaces or garages.
2.  Improper installation, 
adjustment, alteration, service, 
or maintenance can cause 
personal injury or property 
damage.
3.  To reduce the risk of fire, 
use only ductwork materials 
deemed acceptable by state, 
municipal and local codes.
NOTES:
1.  Best performance is achieved 
by using round duct instead of 
rectangular, especially when 
elbows are required.  
2.  If multiple elbows are needed, 
ensure that there is a minimum 
of 24” of straight duct between 
any two elbows. 
3.  Avoid “S” or “back to back” 
configurations caused by 
adjacent elbows. 
4.  Thermal breaks, such as a 
short section of non-metallic 
duct, should be used in areas 
of extreme cold.  
5.  A back-draft damper at the duct 
outlet may also be required.
6.  Do not use flexible metal duct. 
7.  Do not use ductwork that is 
smaller in cross-sectional area 
than the recommended size 
duct.
Stiffener Channel Location
RV Overall Dimensions
Front View
30” - RV30
36” - RV36
46” - RV46
COOKTOP
8”
26 11/16”
Top Cap
Vent Sleeve
(in raised position)
Countertop
Raised Vent
RV30/36/46
Vent Junction Box
120VAC, 15A, Grounded
Junction Box (not provided)
Support Leg
3 1/4” x 10” Duct
2 1/2”
1 13/16”
1/2”
2 1/4”
1/2”
2”
3”
1/4” min. of flat
3/4”
Overall Dimensions