Dacor RV30X Installationsanleitung

Seite von 12

wARNINgS:
1.  To reduce the risk of personal 
injury caused by reaching 
over a hot appliance, cabinet 
storage space located directly 
above the cooktop should be 
avoided.
2.  Do not store combustible 
materials or items adversely 
affected by heat in cabinet 
areas above the appliance.
3.   Follow the instructions 
regarding minimum safe 
clearances and installation 
location. Failure to do so may 
result in a fire or safety hazard.
NOTE:
when installing the cooktop and 
vent into a laminated (Formica®, 
etc.) or synthetic (Corian®, etc.) 
countertop, follow the countertop 
manufacturer’s instructions 
regarding the minimum corner 
radius, use of heat reflective tape, 
reinforcement of corners, etc.
Plan the installation so that all required 
minimum clearances between the cooktop, 
overhead cabinets and adjacent vertical walls 
are provided. Refer to the cooktop installation 
instructions for the minimum dimensions specific 
to the particular appliance being installed.
The DACOR Raised Vent System is designed 
to remove the contaminants and by-products 
that result when cooking with gas or electric 
appliances. The vent system consists of the vent 
intake along with a remote blower or a cabinet 
blower. The raised vent downdraft systems 
are compatible for use with select DACOR 
cooktops, therefore, these instructions offer 
specific guidelines for mounting the raised vents 
behind DACOR cooktops.
t=max. backsplash thickness
25"
B
C
A
D
Combustible
Rear Wall
Cutout and Overall Dimensions
(CER304, CER365, ETT304, ETT365, SGM466, SGM464GG)
Countertop Preparation
Below Countertop Preparation
The raised vent intake, blower (in cabinet 
mounted models only), and cooktop are 
designed for installation into standard U.S. 
made base cabinets. Before making the 
countertop cutout, make certain that the cooktop 
and vent system will clear the cabinet walls, 
backsplash, and any wall studs along the back 
wall within the cabinet.
Dacor
Model No.
Cutout
“A”
Cutout
“B”
Cutout
“C”
Cutout
“D”
Dimension
“t”, max.
Overall
width
CER304
19 7/8”
28 1/2”
27 1/2”
2 3/8”
3/4”
30”
CER365
19 7/8”
34 1/2”
33 1/2”
36”
ETT304
19 7/8”
28 1/2”
27 1/2”
30”
ETT365
19 7/8”
34 1/2”
33 1/2”
36”
SGM304
22 1/4”
27 1/2”
27 1/2”
30”
SGM364
22 1/4”
33 3/4”
33 1/2”
36”
SGM365
22 1/4”
33 3/4”
33 1/2”
36”
SGM466
19 7/8”
44 1/2”
43 1/2”
46”
NOTES: 
1.   If there is a backsplash with a 
curved base at the countertop 
level, then the clearance 
behind the vent will be 
reduced. keep this in mind to 
avoid interference.
2.   If your cabinet differs from the 
standard 24” deep, 36” high 
cabinets, then adjust your 
cutout locations accordingly to 
prevent interference.
3.  If a drawer or shelf is being 
installed below a gas cooktop, 
be certain to avoid interference 
with the gas supply line and 
the drawer or shelf.
4.  For installation with gas 
cooktops, a 90-degree elbow 
must be connected to the 
cooktop gas inlet to avoid 
interference with the Raised 
Vent plenum front.
Locate the house junction box adjacent to the 
vent junction box found at the lower right of the 
vent plenum.
t=max. backsplash thickness
25"
B
A
Combustible
Rear Wall
Cutout and Overall Dimensions
(SGM304, SGM364, SGM365)
Finished 
Countertop
11/16" (17mm) to 3 11/16" (94mm)
to right of centerline
3 1/2" x 10 1/4"
(89mm x 260mm)
Optional
8"
 (203mm)
30 13/16"
(783mm)
Rear edge of
cooktop/vent
cutout
plumbed down
Down Duct Cutout Dimensions
RV with CABP3 Blower
NOTE:
Access from the front of the 
cabinet to the underside of the 
cooktop, the vent system, and the 
junction box must be provided 
for inspection and service. Any 
drawers or shelves placed below 
the cooktop and in front of the 
vent must be easy to remove for 
access to the cooktop, vent and 
junction box.
For installation of the raised vent system, 
provide an opening in the countertop as shown 
in the Countertop Preparation Section. Position 
the cutout so all required minimum clearances 
are met. Make certain that the minimum flat 
countertop area meets or exceeds the combined 
overall width and overall depth, as shown.
NOTE:
Verify that the raised vent and 
blower being installed are a 
matched pair before beginning the 
installation.