Maytag MHN30PDCWW Installationsanweisungen

Seite von 32
5
Washer Dimensions
A floor drain should be provided under the bulkhead. Prefabricated 
bulkheads with electrical outlets, water inlet lines, and drain facilities 
should be used only where local codes permit.
Drain System
The washer can be installed using the standpipe drain system  
(floor or wall), the laundry tub drain system, or the floor drain 
system. Select the drain hose installation method you need.  
See “Tools and Parts.”
Standpipe drain system – wall or floor (views A & B)
The standpipe drain requires a minimum diameter standpipe  
of 2" (50 mm). The minimum carry-away capacity can be no less 
than 10 gal. (38 L) per minute, per washer.
The top of the standpipe must be at least 30" (762 mm) high  
and no higher than 96" (2.4 m) from the bottom of the washer.
30" min.
(762 mm)
Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L) capacity. The top 
of the laundry tub must be at least 30" (762 mm) above the floor.
Floor drain system (view D)
The floor drain system requires a siphon break that may be 
purchased separately. See “Tools and Parts.”
The siphon break must be a minimum of 28" (710 mm) from  
the bottom of the washer. Additional hoses might be needed.
30" min.
(762 mm)
28" min.
(710 mm)
Location Requirements
Selecting the proper location for your washer improves 
performance and minimizes noise and possible washer “walk.”
Your washer can be installed under a custom counter, or in a 
basement, laundry room, or recessed area. See “Drain System.”
Companion appliance location requirements should also be 
considered. Proper installation is your responsibility.
You will need
 
A water heater set to deliver 120°F (49°C) water to the washer.
 
A grounded electrical outlet located within 6 ft. (1.8 m) of 
where the power cord is attached to the back of the washer. 
See “Electrical Requirements.”
 
Hot and cold water taps located within 4 ft. (1.2 m) of the hot 
and cold water fill valves, and water pressure of 20–100 psi 
(137.9–689.6 kPa).
 
A level floor with a maximum slope of 1" (25 mm) under entire 
washer. Installing the washer on soft floor surfaces, such as 
carpets or surfaces with foam backing, is not recommended.
 
A sturdy and solid floor to support the washer with a total 
weight (water and load) of 400 lbs (180 kg).
Do not operate your washer in temperatures below 32°F (0°C). 
Some water can remain in the washer and can cause damage 
in low temperatures.
Installation clearances
 
The location must be large enough to allow the washer door  
to be fully opened.
 
 Additional spacing should be considered for ease of 
installation and servicing. The door opens more than 90°,  
and it is not reversible.
 
 Additional clearances might be required for wall, door,  
and floor moldings.
 
 Additional spacing of 1" (25 mm) on all sides of the washer  
is recommended to reduce noise transfer.
 
Companion appliance spacing should also be considered.
A  
B
C    
D
Door is not reversible
50
1
/
2
"
(1282 mm)
37
13
/
16
"
(961 mm)
27"
(686 mm)
28
13
/
16
"
(732 mm)
44
5
/
8
"
(1134 mm)