Dacor DYRP48DSNGH Installationsanweisungen

Seite von 22
7
Preparing for Installation
 
WARNING
• 
If the gas or electric service provided does not meet the 
product specifications, do not proceed with the installation. 
Call the dealer, the gas supplier or a licensed electrician.
• 
Before installing the range, you must locate and secure the 
anti-tip bracket to the floor.
IMPORTANT: Within the Commonwealth of Massachusetts, this 
appliance must be installed by a licensed plumber or gas fitter.
Unpacking the Range
Unpack the parts box and verify that all required components 
have been provided. If any item is missing or damaged, please 
contact your dealer immediately. Do not install a damaged or 
incomplete appliance.
Installation Instructions
Parts List
- 3 Grates
- 8 Standard burner caps 
  (4 brass, 4 porcelain)*
- 4 Standard burner rings
- 4 SimmerSear burner caps 
  (2 brass, 2 porcelain)*
- 2 SimmerSear burner rings
- 2 SimmerSear burner heads
- 2 GlideRack™ oven racks 
- 1 Standard rack
- 2 GlideRack™ 18” wide oven 
  racks (DYRP48D only)
- 1 18” wide standard oven rack  
  (DYRP48DS only)
- 6 Knobs (4 Standard,  
  2 MAX GRIDDLE)
- Anti-tip bracket with screws 
and anchors
- Meat probe
- Griddle
- Wok ring
- Stainless steel cleaner
- Literature kit
- Broiler pan/grill
*The range is supplied with two different types of burner caps 
(brass and porcelain) to suit the customer’s preference.
Installing a Downdraft Vent (Optional)
Install the downdraft vent before installing the range. See the 
installation instructions included with the downdraft vent.
IMPORTANT: The downdraft vent attaches to the narrow back 
portion of the cutout. It is self-supporting in the cutout and does 
not actually attach to the range itself.
Installing a Backguard (Optional)
Install the backguard before making the range gas and electrical 
connections. Install it according the installation instructions 
included with the backguard kit.
Approved backguard kits: 
Model
Description
APB36D3 3 inch high backguard for range model DYRP36DS
APB36D9 9 inch high backguard for range model DYRP36DS
APB48D3 3 inch high backguard for range model DYRP48DS
APB48D9 9 inch high backguard for range model DYRP48DS
Install the Anti-Tip Bracket and Foot
Locate the anti-tip bracket included in the parts box.
There are two ways to mount the anti-tip bracket:
• 
Floor mounting (preferred method)
• 
Wall mounting (alternate method). Use this method if floor 
mounting is not suitable. If the front panel of range is further 
than 26 1/2” (67.3 cm) from the back wall or if the flooring is 
too thick (see Installing the Anti-Tip Bracket on the Wall), 
the wall mounting method may not be used and the floor 
mounting method must be suitable.
Installing the Anti-Tip Bracket on the Floor 
 
WARNING
To perform its intended function, the anti-tip bracket must be 
attached as instructed to the concrete slab or wood sub-floor 
below any floor coverings (including cement board) on top. Do 
not attach the anti-tip bracket directly to floor coverings such as 
ceramic/asphalt tile or linoleum.
Four (4) plastic anchors are provided along with three sizes (4 
each) of #8 or #12 Phillips head screws for attaching the anti-
tip bracket to the floor. Use both the anchors and four (4) of the 
screws when attaching the bracket to a concrete sub-floor. Do not 
use the provided anchors when attaching to a wood sub-floor.
    continued...
Sub-floor
Screws attached to  
sub-floor below floor 
covering
Anti-tip
bracket
Floor 
covering
Concrete anchors shown, do
not use for wood sub-floor