6
Cabinet Layout
• 
All maximum and minimum dimensions and clearances 
shown in the diagrams below must be maintained for safe 
operation.
• 
Check the location where the range is to be installed. It 
should be placed away from drafts that may be caused by 
doors, windows and heating and air conditioning outlets. 
• 
To reduce the risk of fire or personal injury from reaching over 
a hot appliance, avoid cabinet installations directly above the 
range. If cabinet storage is to be provided, the risk can be 
reduced by installing a range hood that projects horizontally a 
minimum of 5 inches beyond the bottom of the cabinets.
• 
The range may be installed flush to the rear wall. Dacor 
strongly recommends installing a non-combustible material 
on the rear wall above the range and up to the vent hood or 
installation of a backguard. It is not necessary to install non-
combustible materials behind the range below the countertop 
height. Any openings in the wall behind the appliance or in 
the floor underneath it must be sealed.
Gas and Electrical Service
• 
The shaded area shown below denotes the location of the 
gas inlet and the electrical junction box/receptacle. This is 
the recommended location. For replacement purposes, the 
location of the existing utilities may be utilized provided they 
do not interfere with the sides or rear of the range. Check 
local building codes for permissible gas valve locations.
• 
An external manual shut-off valve must be installed between 
the gas inlet and the range for the purpose of turning on or 
shutting off gas to the appliance.
The installation must allow for the following:
• 
Access to the gas shut-off valve when the unit is installed.
• 
Access to the remote circuit breaker panel/fuse box, when the 
range is in place.
• 
The gas supply piping and shut-off valve, and the electrical 
junction box/receptacle must be located so they do not 
interfere with the range when it is installed.
• 
The junction box and gas shut off valve must be located 
so that the range can be pulled out for service while the 
appliance remains connected.
Note 2
F
G
2
 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
3
 Consult local code for exact location requirements.
1
 Vertical from range grate level to combustible overhead 
surface; if installing an overhead vent hood, also check  
hood specifications for minimum required clearances. 
4
 Vertical from grate level to combustible surface.
Non-combustible 
surface along back wall 
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2  cm)
min.
1
37 1/2” 
(95.3 cm)
max.
13” (33.0 cm)
max.
5
15” (38.1 cm)
min.
4, 5
5
 This specification does not apply for cabinets more 
than a horizontal distance of 10” (25.4 cm) from the 
edge of the range.
Suggested 
location of 
utilities
 
3
Grate 
level
G
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
non-combustible
rear wall recommended
Backsplash
3/8" (1.0 cm)
Min. flat countertop
overhang
H
3” (7.6 cm)
Note 2
Cutout tolerances: +1/16” (+1.6 mm), -0 
unless otherwise stated
CUTOUT DIMENSIONS
Range Model
F
G
H
DYRP36D[-C-]S 42” (106.7 cm)* 
36” (91.4 cm)**
36” 
(91.4 cm)**
33 1/2” 
(84.8 cm)
DYRP48D[-C-]S 54” (137.2 cm)* 
48” (121.9 cm)**
48” 
(121.9 cm)**
43 1/2” 
(110.2 cm)
* Recommended ** Minimum
APPROVED DOWNDRAFT MODEL NUMBERS
Range Model
Downdraft Vent Model
DYRP36D[-C-]S
ERV36-ER
DYRP48D[-C-]S
ERV48-ER
Standard Cutout with 
Range Hood
Cutout with Optional Downdraft Vent 
(Top View)
IMPORTANT: See the downdraft installation instructions 
for duct and electrical installation requirements. Use only 
the Dacor downdraft vent models specified above.
Planning the Installation