Maytag MGDB855D Installationsanweisungen

Seite von 44
5
Parts needed: 
(Not supplied with dryer)
Check local codes. Check existing electrical supply and venting. 
See “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system hardware 
available for purchase from the dealer from whom you purchased 
your dryer. For further information, please refer to the “Assistance 
or Service” section in your “Use and Care Guide.”
Optional Equipment:
 (Not supplied with dryer) 
Refer to your “Use and Care Guide” for information about 
accessories available for your dryer.
LOCATION REQUIREMENTS
You will need:
 
A location allowing for proper exhaust installation.  
See “Venting Requirements.”
 
A separate 15 or 20-amp circuit needed for gas dryers and 
30-amp circuit needed for electric dryers.
 
If using power supply cord, a grounded electrical outlet  
located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
 
Floor must support dryer weight of 200 lbs. (90.7 kg).  
Also consider weight of companion appliance.
 
Level floor with maximum slope of 1" (25 mm) under entire 
dryer. If slope is greater than 1" (25 mm), clothes may not 
tumble properly and automatic sensor cycles may not 
operate correctly.
 
For garage installation, place dryer at least 18" (460 mm) 
above floor. 
 
Steam models only: Cold water faucets located within 4 ft. 
(1.2 m) of the water fill valves, and water pressure of 20-100 
psi (137.9-689.6 kPa). You may use the water supply for your 
washer using the “Y” connector and short hose which are 
provided.
IMPORTANT: Do not operate, install, or store dryer where  
it will be exposed to water, weather, or at temperatures below  
45° F (7° C). Lower temperatures may cause dryer not to  
shut off at end of automatic sensor cycles, resulting in longer  
drying times.
NOTE: No other fuel-burning appliance can be installed in the 
same closet as a dryer.
DRYER DIMENSIONS
INSTALLATION CLEARANCES
For each arrangement, consider allowing more space for ease of 
installation and servicing; spacing for companion appliances and 
clearances for walls, doors, and floor moldings. Space must be 
large enough to allow door to fully open. Add spacing on all sides 
of dryer to reduce noise transfer. If a closet door or louvered door 
is installed, top and bottom air openings in door are required.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
NOTE: Most installations require a minimum of 6" (152 mm) 
clearance behind dryer for exhaust vent with elbow. See  
“Venting Requirements.”
Bottom view:
8
1
/
2
"
(218 mm)
14
3
/
8
"
(365 mm)
42
13
/
16
"
(1087 mm)
3
5
/
8
"
(93 mm)
1
/
2
"
(13 mm)
32
5
/
16
"
(821 mm)
56
1
/
4
"
(1428 mm)
11
3
/
8
"
(289 mm)
Door Opened
Door Closed
5
7
/
8
"
(150 mm)
3
1
/
2
"
(93 mm)
4
1
/
2
"
(115 mm)
3"
(77 mm)
29"
(737 mm)
14
1
/
2
"
(370 mm)
1
3
/
8
"
(35 mm)
Back view