Frigidaire FFGS3025PS Installationsanweisungen

Seite von 44
8
30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with Sealed Top Burners)
Once regulator is in place, open the shutoff valve in the 
gas supply line. Wait a few minutes for gas to move 
through the gas line.
Check for leaks. After connecting the range to the gas 
supply, check the system for leaks with a manometer. 
If a manometer is not available, turn on the gas supply 
and use a liquid leak detector (or soap and water) at all 
joints and connections to check for leaks.
 Do not use a flame to check for leaks 
from gas connections. Checking for leaks with a flame 
may result in a fire or explosion.
Tighten all connections as necessary to prevent gas 
leakage in the range or supply line.
Disconnect this range and its individual manual 
shutoff valve from the gas supply piping system 
during any pressure testing of that system at test 
pressures greater than 1/2 psig (3,5 kPa or 14" water 
column).
Isolate the range from the gas supply piping 
system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig 
(3,5 kPa or 14" water column).
5.
 LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use with 
natural gas.
If you wish to convert your range for use with LP/
Propane gas, use the supplied fixed orifices located 
in a bag containing the literature marked "FOR 
LP/PROPANE GAS CONVERSION". Follow the 
instructions packaged with the orifices for surface, 
oven and broil burners conversion.
The conversion must be performed by a qualified 
service technician in accordance with the 
manufacturer's instructions and all local codes and 
requirements. Failure to follow these instructions 
could result in serious injury or property damage. 
The qualified agency performing this work assumes 
responsibility for the conversion.
 Failure to make the appropriate 
conversion can result in serious personal injury and 
property damage.
6.
 Electrical Requirements
120 volt, 60 Hertz, properly grounded dedicated circuit 
protected by a 15 amp circuit breaker or time delay 
fuse.
Note: Not recommended to be installed with a Ground 
Fault Interrupt (GFI).
Do not use an extension cord with this range.
Preferred Method
Grounding type 
wall receptacle
Do not, under any 
circumstances, 
cut, remove, 
or bypass the 
grounding prong.
Power supply cord with 
3-prong grounding plug.
Figure 5
Grounding Instructions
IMPORTANT Please read carefully.
For personal safety, this appliance must be 
properly grounded.
The power cord of this appliance is equipped with a 
3-prong (grounding) plug which mates with a standard 
3-prong grounding wall receptacle (see Figure 5) to 
minimize the possibility of electric shock hazard from 
the appliance.
The wall receptacle and circuit should be checked by 
a qualified electrician to make sure the receptacle is 
properly grounded.
Where a standard 2-prong wall receptacle is installed, 
it is the personal responsibility and obligation of the 
consumer to have it replaced by a properly grounded 
3-prong wall receptacle.
Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.
 Disconnect electrical supply cord from 
wall receptacle before servicing the appliance.
7.
 Moving the Appliance for 
Servicing and Cleaning
Turn off the range line fuse or circuit breakers at 
the main power source, and turn off the manual gas 
shut-off valve. Make sure the range is cold. Remove 
the service drawer (warmer drawer on some models) 
and open the oven door. Lift the range at the front 
and slide it out of the cut-out opening without creating 
undue strain on the flexible gas conduit. Make sure 
not to pinch the flexible gas conduit at the back of the 
range when replacing the unit into the cut-out opening. 
Replace the drawer, close the door and switch on the 
electrical power and gas to the range.