30" GAS SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
(Models with Sealed Top Burners)
2.
 Provide an adequate Gas Supply
When shipped from the factory, this unit is designed 
to operate on 4" (10,16 cm) water column (1.0 kPa) 
Natural gas manifold pressure. A convertible pressure 
regulator is connected to the range manifold and 
MUST be connected in series with the gas supply line. 
If LP/Propane conversion kit has been used, follow 
instructions provided with the kit for converting the 
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to 
obstruct the flow of combustion and ventilation air.
For proper operation, the maximum inlet pressure 
to the regulator should be no more than 14" (35,56 
cm) of water column pressure (3,5 kPa). The inlet 
pressure to the regulator must be at least 1" (0,25 kPa) 
greater than the regulator manifold pressure setting. 
Examples: If regulator is set for natural gas 4" (10,16 
cm) manifold pressure, inlet pressure must be at least 
5" (12,7 cm); if regulator has been converted for LP/
Propane gas 10" (25,4 cm) manifold pressure, inlet 
pressure must be at least 11" (27,9 cm).
Leak testing of the appliance shall be conducted 
according to the instructions in step 4.
The gas supply line should be ½" or ¾" I.D. (Interior 
Diameter)
3.
 Seal the openings
Seal any openings in the wall behind the range and 
in the floor under the range after gas supply line is 
installed.
4.
 Connect the range to the gas 
supply
Important: Remove all packing material and literature 
from range before connecting gas and electrical 
supply.
To prevent leaks, put pipe joint sealant on all external 
pipe threads.
Your regulator is in location as shown in figure 3.
 
Do not allow regulator to rotate on 
pipe when tightening fittings.
Connection to Pressure Regulator
The regulator is already installed on the appliance.
 Do not make the connection too tight. 
The regulator is die cast. Overtightening may crack the 
regulator resulting in a gas leak and possible fire or 
explosion.
Assemble the flexible connector from the gas supply 
pipe to the pressure regulator in the following order:
1.  manual shutoff valve (not included)
2.  1/2" nipple (not included)
3.  1/2" flare union adapter (not included)
4.  flexible connector (not included)
5.  1/2" flare union adapter (not included)
6.  1/2" nipple (not included)
7.  pressure regulator (included)
Use pipe-joint compound made for use with Natural 
and LP/Propane gas to seal all gas connections. If 
flexible connectors are used, be certain connectors are 
not kinked.
The supply line must be equipped with an approved 
manual shutoff valve. This valve should be located 
in the same room as the range and should be in a 
location that allows ease of opening and closing. 
Shutoff Valve -
Open position
to appliance
to gas suppl
y line
Figure 4
•  If you are using a through the floor gas entry, remove 
the line protector shield from the bottom of the unit to 
allow access for the pipe line (figure 3).
•  We recommend to install a pipe elbow right out of the 
floor or wall towards the center of the unit to ease the 
installation.
To remove the line protector, remove the 3 
screws.
Figure 3
Gas pressure regulator location
Do not block 
access to the 
shutoff valve. 
The valve is 
for turning on 
or shutting 
off gas to the 
appliance.
All connections must be wrench-tightened
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Pressure
Regulator
On
Off
Flexible
Connector
Access
Cap
Nipple
Nipple