Dacor RNRP36G Installationsanweisungen

Seite von 16
7
ANTI-TIP BRACKET PLACEMENT
Dimension
RNRP36G
RNRP48G
A
10 7/8” (27.6 cm)
1 1/2” (3.8 cm)
B
22 1/2” (57.2 cm)
22 1/2” (57.2 cm)
* Excludes bull nose (see page 4)
SCREW SIZE TABLE
Sub-Floor Type/Floor 
Covering Thickness
Screw Size
Concrete or wood sub-
floor, no floor covering over 
top
#8 x 1 *
Concrete or wood sub-
floor, floor covering up to 
1/4” thick
#8 x 1 *
Concrete or wood sub-
floor, floor covering over 
1/4” and up to 1/2” thick
#8 x 1 1/4 *
Wood sub-floor, floor 
covering over 1/2” and up 
to 1 3/16” thick
#12 x 1 3/4 *
Concrete under floor 
covering over 1/2” thick
Must be purchased separately **
Wood sub-floor, floor 
covering over 1 3/16” thick
Must be purchased separately **
* Included with range
** Determine required depth based on information in step 3 and 
purchase from local hardware store.
Installing the Anti-Tip Bracket on the Floor 
(cont.)
1.  Determine the location of the range center line and front 
panel for the range’s final position based on the Product 
Dimensions on page 5 and the actual cabinet/cutout 
dimensions used for the installation.
2.  Determine the required position of the anti-tip bracket, based 
on the diagram below. Mark the four (4) mounting hole 
locations on the floor with a pencil.
3.  Determine the screw size required. The minimum full thread 
depth (portion of screw threaded into wood/slab) for wood is 
3/8” (1 cm) and 5/8” (1.6 cm) for concrete. See 
SCREW SIZE 
TABLE to select the correct screw size.
Attaching the bracket to a concrete floor:
• 
Drill four (4) 3/8” diameter countersink holes through any 
existing floor covering down to the concrete slab below.
• 
Drill the 4 holes for the anchors 1 1/4” (3.2 cm) deep into the 
concrete slab using a 3/16” masonry bit. This hole length is 
longer than the anchor, but is required for proper installation. 
Clear the holes of dust and any other material. Tap each 
anchor into the hole until the anchor top is flush with the top 
of the concrete slab. Position the anti-tip bracket holes over 
the anchor holes. Insert the screws through the 4 holes in 
the base of the bracket and thread them into the anchors. Be 
sure the screw threads fully engage the anchor body. Tighten 
the screws into place.
Attaching the bracket to a wood floor:
• 
If there is ceramic, asphalt or other hard floor covering over 
the wood below, drill (4) countersink holes to allow access to 
the wood below for drilling pilot holes.
• 
Drill four (4) pilot holes into the wood floor using a drill bit 
(1/16” dia. for #8 screws, 1/8” dia. for #12 screws). Position 
the anti-tip bracket holes over the holes in the floor. Insert the 
screws into the wood and tighten into place.
Installation Instructions
CL
B
Anchor, 4 places:
use for concrete
floor only
Range 
center line
Range front 
panel*
TOP VIEW
#8 x 1”
#8 x 1 1/4” or
#12 x 1 3/4
screw,
4 places
(see text)
A