Amana AGR5330BAB Installationsanweisungen

Seite von 16
6
Gas Supply Requirements
Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition.
IMPORTANT: Leak testing of the range must be conducted 
according to the manufacturer’s instructions. See “Complete 
Connection” in the “Make Gas Connection” section. 
Type of Gas 
Natural gas:
This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. The model/
serial rating plate located on the left side of the bottom of the 
broiler has information on the types of gas that can be used. 
If the types of gas listed do not include the type of gas 
available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.
Gas Supply Line 
Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the 
range location. A smaller size pipe on longer runs may result 
in insufficient gas supply. With LP gas, piping or tubing size 
can be ½" (1.3 cm) minimum. Usually, LP gas suppliers 
determine the size and materials used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®†
 tape. 
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft 
(122 to 152.4 cm) long, ½" (1.3 cm) or ¾" (1.9 cm) I.D., 
flexible metal appliance connector may be used for 
connecting range to the gas supply line. 
A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator.
Do not kink or damage the flexible metal tubing when 
moving the range.
Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff 
valve. This valve should be located in the same room but 
external to the range opening, such as an adjacent cabinet. It 
should be in a location that allows ease of opening and 
closing. Do not block access to shutoff valve. The valve is for 
turning on or shutting off gas to the range.
Gas Pressure Regulator
The gas pressure regulator supplied with this range must be 
used. The inlet pressure to the regulator should be as follows for 
proper operation:
Natural gas:
Minimum pressure: 5" WCP
Maximum pressure: 14" WCP
LP gas:
Minimum pressure: 11" WCP
Maximum pressure: 14" WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A
B
C