Gas Connection
 WARNING
•  Make sure the gas is turned off at the gas supply 
valve before connecting the gas line.
•  Verify that the gas supply meets specifications before 
connection. See page 5.
•  Do not apply excessive pressure when tightening gas 
connections and fittings.
•  Do not use Teflon tape or plumber’s putty on flexible 
gas line connections.
•  Test the gas lines for leaks as instructed before use. 
If a leak is detected, open all doors and windows and 
allow the gas to dissipate before fixing the leak and 
testing the unit.
•  Do not use a flame to check for leaks.
•  The maximum gas supply pressure to the regulator 
must never exceed 1/2 pounds per square inch (psi) 
or 3.5 kPa.
•  The range and its individual shutoff valve must be 
disconnected from the gas supply piping system 
during any pressure testing of that system at test 
pressures in excess of 1/2 psi (3.5 kPa).
•  The range must be isolated from the gas supply 
piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 
1/2 psi (3.5 kPa).
•  For LP gas installations, the LP gas tank must have 
its own high-pressure regulator in addition to the 
pressure regulator installed on the range.
IMPORTANT: The installed gas pressure regulator is pre-
set at the factory for the type of gas intended for use with 
the appliance. Verify that the appliance is compatible with 
the type of gas available by checking the product data label 
attached to the appliance. Ranges intended for use with 
LP gases will have “LP” as a part of the model number. 
Consult your dealer if the range is not compatible with your 
gas supply.
1.  Make sure the gas supply valve is in the off position 
and the range power cord is disconnected.
2.  Connect a flexible gas supply line to the gas shut-off 
valve previously installed on the stub out. The gas 
line needs to be long enough to allow the range to be 
pulled out for service.
3.  Connect the gas line to the regulator on the back of the 
range.
4.  Turn all cooktop control valves to the 
“OFF” position.
5.  Turn on the gas supply valve and check 
all lines and connections for leaks using a 
soap and water solution or an electronic 
gas leak detector.
6.  Turn the gas supply off.
Gas Line 
Connection
“OFF” 
symbol on 
knob
1/2” male NPT 
connection*
Installation Instructions
* 3/4” male NPT connection may be used 