Dacor CABP3 Installationsanweisungen

Seite von 8
2
Installation Planning
A qualified technician must complete the 
installation of this appliance.
Carefully check the location where the remote 
blower is to be installed. The remote blower 
should be placed for convenient access. Make 
certain that electrical power can be provided in 
the selected location.
Plan the installation so that all minimum 
clearances are met or exceeded. Dimensions 
shown provide minimum clearances, unless 
otherwise noted.
NOTES: 
1.  All dimensional tolerances are 
+ 1/16”, - 0” unless otherwise 
stated.
2.  Before commencing 
installation, remove the top 
cover of the remote blower 
(REMP ONLY). Check to see 
if the blower wheel turns 
freely. Do not replace the top 
cover until the installation is 
complete.
Model 
No.
Overall Chassis 
Width “A”
Overall Chassis 
Height “B”
Overall Chassis 
Length “C”
Duct Diameter 
“D”
ILB8
10 5/8” (270mm)
10 1/2” (267mm)
5” (127mm)
8” (203mm)
ILB10
12 5/8” (321mm)
12 1/2” (318mm)
10” (254mm)
Model 
No.
Electrical Supply 
Requirements
Maximum
Duct Length
Total 
Connected
Load
Blower
Rating*
Approximate
Shipping Weight
ILB8
Refer to Ventilator
Specifications
Max. 60 
Equivalent
Straight Feet
0.1kW (1A)
500 CFM
15 lbs.
ILB10
0.2kW (2A)
900 CFM
18 lbs.
ILB Overall Dimensions
ILB Specifications
Model 
No.
Overall Chassis 
Width
Overall Chassis 
Height
Overall Chassis 
Length
Duct Diameter
REMP3
19” (483mm)
5 13/16” (148mm)
25 1/2” (648mm)
8” (203mm)
REMP16
26” (660mm)
9 9/16” (243mm)
33 1/2” (851mm)
10” (254mm)
Model 
No.
Electrical 
Supply 
Requirements
Maximum
Duct Length
Total 
Connected
Load
Blower
Rating*
Approx.
Shipping 
Weight
Finish
REMP3
Refer to 
Ventilator
Specifications
Max. 60 
Equivalent
Straight Feet
0.5kW (4A)
620 CFM
35 lbs.
Galvanized
(may be
 painted)
REMP16
0.3kW (3A)
980 CFM
55 lbs.
REMP Overall Dimensions
REMP Specifications
"A"
"B"
Attachment
Surface
ROTATION
AIRFLOW
12
0V
, 60H
z, 1
5A
 P
O
WE
R
 S
U
P
P
LY
C
A
U
TIO
N
: D
IS
C
O
NN
E
C
T P
O
WE
R
 S
U
P
PL
Y A
T T
HE
 FU
S
E BOX B
EFORE SE
R
VICING T
H
IS EQ
UIP
MENT
FAN MO
TOR
G
R
N
DA
CO
R P/N 85
829
WIRING DIAGRAM, ILB-8
M
BK
L
"C"
"D"
Attachment
Surface
Electrical
Access Panel
ILB Overall Dimensions
Front View
ILB Overall Dimensions
Side View
17 1/8" (435mm)
19" (483mm)
24 1/16"
(611mm)
3 5/8"
(92mm)
9 1/4"
(235mm)
Mounting
Flange
25 1/2"
(648mm)
7 1/2"
(191mm)
9 1/2" (241mm)
Discharge
Cutout
Location
Intake Collar
Power Supply
Conduit
Location
CL
CL
CL
CL
REMP3 Overall Dimensions
Top View
5 13/16"
(148mm)
8"
(203mm)
7 13/16"
(198mm)
Discharge
Intake Collar
REMP3 Overall Dimensions
Side View
24" (610mm)
26" (660mm)
31 1/2"
(800mm)
3 1/2"
(89mm)
12 1/4"
(311mm)
Mounting
Flange
33 1/2"
(851mm)
9 1/2"
(241mm)
12 11/16" (322mm)
Discharge
Cutout
Location
Intake Collar
Power Supply
Conduit
Location
CL
CL
CL
CL
REMP16 Overall Dimensions
Top View
9 9/16"
(243mm)
10"
(254mm)
11 1/2"
(292mm)
Discharge
Intake Collar
REMP16 Overall Dimensions
Side View
* All the CFM Blower Ratings are valued at 0” (zero-inch) static pressure.