Dacor PHW Installationsanweisungen

Seite von 16

InstallatIon InstructIons
Hanging the blower assembly
 WARNING
Do not use screws to attach the duct work to the 
exhaust outlet. Use duct tape only. Screws may 
prevent the damper flaps on the top of the hood from 
opening.
Inside the exhaust outlet on the top of the blower 
assembly, there are metal or plastic damper flaps. The 
flaps close to help prevent back-drafts when the blower 
is turned off. Remove the shipping tape and make sure 
the flaps open and close freely before proceeding.
Lift the blower assembly up and put the mounting hole 
on the top over the mounting bracket, while inserting 
the exhaust outlet into the end of the duct system. 
Gently lower the blower assembly onto the lip of the 
mounting bracket. Slide the bottom part of the blower 
assembly between the two “L” brackets.
1.
2.
Insert two provided machine screws into the two holes 
above the mounting bracket on the blower assembly 
and tighten into place.
Insert two machine screws through the front of the 
mounting bracket and tighten into place.
Insert two machine screws through the side of both “L” 
brackets and tighten into place. 
Attach the end of the duct system to the exhaust outlet 
with duct tape.
3.
4.
5.
6.
ExHAUST 
OUTLET
“L” BRACKETS
MOUNTING 
BRACKET
INSERT ExHAUST 
OUTLET INTO 
END OF DUCT