Locate the chimney mounting bracket and position it 
against the ceiling as shown. Center it on the vertical 
center line drawn on the wall.
Mark the ceiling in two places through the holes in the 
top of the bracket. Remove the bracket from the ceiling.
Drill 5/16” holes through the two spots marked on the 
ceiling.
Insert the two of the provided wall anchors into the 
holes on the ceiling.
Place the chimney mounting bracket against the ceiling 
and attach it using two included 1 1/2” screws.
Install blower Mounting bracket
Find the mounting bracket template in the shipping 
box. Put the template against the wall and line up the 
horizontal line drawn on the wall with the horizontal line 
on the template.
Line up the vertical line drawn on the wall with the 
center line on the template. Iron out all creases and 
folds and tape the template to the wall using tape that 
will not damage the wall finish. 
Using a sharp object, mark the wall through the 
template at the center of the three blower mounting 
bracket hole positions (near the top) and the position of 
the two “L” brackets, near the bottom.
Remove the template.
4.
5.
6.
7.
8.
1.
2.
3.
4.
InstallatIon InstructIons
 WARNING
Do not install the range hood unless the electrical 
service provided meets the range hood specifications.
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
A qualified technician must complete the installation 
of this built-in appliance. The owner is responsible to 
make sure the hood is properly installed.
To avoid an electric shock hazard and property 
damage, locate electric wires and water pipes and 
avoid drilling in the vicinity.
Install the electrical connection
The electrical connection box must be:
Connected to a 120VAC, 60Hz dedicated, grounded, 
circuit protected by a 15 amp circuit breaker or time 
delay fuse.
Located a minimum of 17 inches above the bottom of 
the range hood.
Install the chimney Mounting 
bracket
Determine the vertical center line for the range hood. 
The center line for the hood is usually the same as the 
center line of the range or cooktop. 
Using a pencil, mark the vertical center line on the wall 
from where the bottom of hood will be located to where 
the top of the chimney will be located.
Draw a horizontal line 9 inches long at 90° to the 
vertical center line where the bottom of the hood will be 
located. The minimum allowable distance is 30” above 
the cooktop.
1.
2.
3.
ANCHOR
CHIMNEY
MOUNTING 
BRACKET
 WARNING
The electrical service to the range hood should be  
installed only by a licensed electrician.