Dacor DR30GFSNGH Designanleitung

Seite von 5
All specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
PLANNING
GUIDE
DR30GS, DR30GFS, DR30GIS, DR30GIFS
Distinctive
 
30” Wide 
All Gas Ranges
Document # PG05-007
Revised 04/04/13   Page 2/5
All tolerances +1/16” (+1.6 mm), -0 unless otherwise noted.
a*
B
c
30” min.
(76.2 cm)
36” (91.4 cm) recommended
30” (76.2 cm) min.
37” (94.0 cm) 
max.
FREEStANDING INStALLAtION cAbINEt cUtOUt DImENSIONS - mODELS DR30GS, DR30GFS, DR30GIS AND DR30GIFS
* See the cutout dimensions on following page for self-rimming installations.
 
Failure to meet or exceed the maximum and 
minimum dimensions/clearances stated may result 
in a fire hazard.
 
The range should be placed away from drafts that 
may be caused by doors, windows and heating and 
air conditioning outlets.
 
To eliminate the risk of burns or fire by reaching 
over heated surface units, cabinet storage space 
located above surface units should be avoided. If 
cabinet storage space is to be provided directly 
above the range, the risk of personal injury may be 
reduced by installing a range hood.
 
In all instances, installation of a range hood is highly 
recommended. The hood should project horizontally 
a minimum of five (5) inches beyond the face of 
the cabinets. See the range hood specifications for 
minimum clearances.
 
If installing a raised vent, install only Dacor model 
ERV3015.
 
The range may be installed flush to the rear wall. 
See diagram and notes for rear wall surface 
requirements. It is not necessary to install non-
combustible materials behind the range below the 
countertop height.
 
Any openings in the wall behind the appliance or in 
the floor underneath it must be sealed.
1
 30” (76.2 cm) min. vertical clearance from top of range grates to bottom of uncovered wood or metal cabinet. 24” (61 cm) min. clearance if bottom of 
wood or metal cabinets are protected by not less than 1/4“ (0.6 cm) flame retardant millboard covered with no less than No. 28 MSG sheet steel 0.015” 
(0.04 cm) stainless steel, or 0.024” (0.06 cm) aluminum or 0.020” (0.05cm) copper. 30” (76.2 cm) min. clearance between top of range grates and bottom 
of unprotected wood or metal cabinet. If installing range hood, check the hood specifications for minimum required clearances.
2
 Cabinet/countertop depth is at discretion of customer but cabinet face SHALL NOT protrude further than rear of front panel. See Product Dimensions.
3
 Consult local code and following pages for requirements.
4
 This specification not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from edge of range.
5
 10” (25.4 cm) min. to combustible sidewalls above range (both sides).
6
 Non-combustible surface required for models DR30GIS and DR30GIFS up to vertical distance specified in note 1 or range hood, whichever is lower. Non-
combustible surface recommended, but not required, for models DR30GS and DR30GFS.
Note 2
B
A
Back wall
immediately
behind range
6
Top of
finished
counter
13” (33.0 cm)
max.
4
14” (35.6 cm)
min.
4
C
Suggested
location of
utilities
3
Note 5
Note 1