Dacor DR30GFSLPH Installationsanweisungen

Seite von 24
9
Installing the Anti-Tip Bracket
Locate the anti-tip bracket included in the parts box.
There are two ways to mount the anti-tip bracket:
•  Floor mounting (preferred method)
•  Wall mounting (alternate method). Use this method if 
floor mounting is not suitable. If any of the conditions 
below exist, then the wall mounting method can not be 
used and the floor mounting method must be suitable.
The anti-tip bracket may not be mounted to the wall if:
◊  The wall contains metal stud mounting materials that 
interfere with the anti-tip bracket mounting screws.
◊  The front panel of range is further than the maximum 
distances from the back wall stated on page 11.
◊  The flooring is too thick (see Installing the Anti-Tip 
Bracket on the Wall).
Installing the Anti-Tip Bracket on the Floor.
 WARNING
To perform its intended function, the anti-tip bracket 
must be attached as instructed to the concrete slab 
or wood sub-floor below any floor coverings (including 
cement board) on top. Do not attach the anti-tip bracket 
directly to floor coverings such as ceramic/asphalt tile or 
linoleum.
     continued...
Verifying the Package Contents
Unpack the range and verify that all required parts have 
been provided. If any item is missing or damaged, please 
contact your dealer immediately. Do not install a damaged 
or incomplete appliance. The customer must report 
cosmetic issues immediately to the dealer or builder.
Parts List
Anti-tip bracket with screws and anchors
2 grates
Use and care manual
Stainless steel cleaner
1 dual burner ring
1 outer dual burner cap
1 inner dual burner cap
3 standard burner caps (2 large, 1 small)
3 standard burner rings (2 large, 1 small)
2 standard oven racks 
1 GlideRack oven rack
Installation Instructions
 WARNING
•  If the gas or electric service provided does not meet 
the product specifications, do not proceed with the 
installation. Call the selling dealer, the gas supplier or 
a licensed electrician.
•  This appliance must be installed by a licensed 
plumber or gas fitter when installed within the 
Commonwealth of Massachusetts.
Gas and Electrical Locations
•  Dacor recommends that utility access for all models 
be installed in an adjacent cabinet, as shown on page 
6. If the utilities are installed behind the range, the 
installation must allow for the following:
◊  Access to the gas shut-off valve when the unit is 
installed.
◊  Access to the electrical outlet, when the range is in 
place.
◊  The gas supply piping, gas shut-off valve and the 
electrical outlet must be located so they do not 
interfere with the range when it is installed.
◊  The electrical outlet and gas shut off valve must 
be located so that the range can be pulled out for 
service while the appliance remains connected.
•  Both the gas supply piping and shut-off valve and the 
electrical outlet must be located so they do not interfere 
with the range when it is installed.
 
CL
CL
10” (25.4 cm)
10” (25.4 cm)
12” (30.5 cm)
2 1/2”
(6.4 cm)
3 1/2”
(8.9 cm)
1” (2.5 cm)
•  Existing utility connections may be used for 
replacement purposes, provided they meet local code 
and fit within the utility clearance area at the back of 
the range. See diagram, below.
Installation Specifications
Utility Clearance 
Behind Range