Elica ENM230SS Installationsanweisungen

Seite von 38
8
Lift the range hood up under cabinet and determine final 
  location by centering beneath cabinet. Mark on the underside 
  of cabinet the location of the 4 keyhole mounting slots on the 
  range hood. Set range hood aside on a covered surface. 
 
 
 
 
 
 
 
 
Use ¹⁄
8
” (3 mm) drill bit and drill 4 pilot holes as shown. 
 
 
 
 
 
Install the 4 - 4.5 mm x 13 mm mounting screws in pilot 
 holes. Leave about ¹⁄
4
” (6.4 cm) space between screw heads 
  and cabinet to slide range hood into place. 
 
 
 
 
 
Remove transition knockouts depending on your model. 
 
 
 
 
 
 
 
 
 
 
 
 
 
Round vent system installations - Remove top rectangular 
and round vent knockouts.
Rectangular vent system installations - For roof 
installations, remove the top rectangular vent knockout. For 
wall installations, remove the rear rectangular vent knockout
Non-ducted (recirculating) installations - Do not remove 
any knockouts.
Remove metal grease filters. See the “Range Hood Care” 
 section. For the ENM series models, first remove the lateral 
  panels 
 NOTE: You will have 3 1/4” x 10” (8.3 x 25.4 cm) rectangular 
  vent connector inside your range hood. Some models are 
 recirculation (non-ducted only) and will not have vent 
  connector.
Remove the 3-1/4” x 10” (8.3 x 25.4 cm) rectangular vent 
  connector attached with screws or taped on the inside your 
  range hood. 
1.
2.
3.
4.
5.
6.
A. Keyhole slot
A
A. Drill pilot hole
A
"
(6.4 mm)
A. Round vent knockout
B. Top rectangular vent knockout
C. Rear rectangular vent knockout
A
B
C
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
For round installation: Install 7” (17.8 cm) round vent mounting 
 plate and damper or 3 1/4” x 10” (8.3 x 25.4 cm) vent  
  connector, depending on your vent system installation.  
 (Purchase as an accesory).
7.
A
B
C
D
E
A.Screws
B.3 " X 10" (8.3 X 24.4 cm)
rectangular vent connector
A
B
model: ENM
models:ESN
 
EFS
 
ERS
A. 7" (17.8 cm) Round damper
B. Sheet metal screws 
C. 7" (17.8 cm) round vent mounting plate
D. Round vent knockout
E. Rectangular vent knockout
A. Lateral panels
B. 3-1/4” x 10” (8.3 x 25.4 cm)
rectangular vent connector
A
A
B