Installation Instructions
Verify the Package Contents
Verify that all the components below have been provided. If 
any item is missing or damaged, please contact your dealer 
immediately. Do not install a damaged or incomplete appliance. 
Make sure that you have everything necessary to ensure proper 
installation before proceeding.
•  Use and care manual
•  Anti-tip bracket with screws and anchors
•  Oven racks (2) GlideRack type, (1) standard type
•  Razor blade scraper
•  Dacor Cooktop Cleaning Cream
Installing the Anti-Tip Bracket
Locate the anti-tip bracket included in the parts box.
There are two ways to mount the anti-tip bracket:
• 
Floor mounting (preferred method).
• 
Wall mounting (alternate method). Use this method if floor 
mounting is not suitable. If any of the conditions below exist, 
then the wall mounting method cannot be used and the floor 
mounting method must be suitable.
The anti-tip bracket may not be mounted to the wall if:
◊  The wall contains metal stud mounting materials that 
interfere with the anti-tip bracket mounting screws.
◊  The front panel of the range is further than the maximum 
distance from the back wall stated on page 9.
◊  A downdraft vent is installed.
◊  The flooring is too thick (see Installing the Anti-Tip 
Bracket on the Wall).
Installing the Anti-Tip Bracket on the Floor
 
WARNING
To perform its intended function, the anti-tip bracket must be 
attached as instructed to the concrete slab or wood sub-floor 
below any floor coverings (including cement board) on top. Do 
not attach the anti-tip bracket directly to floor coverings such as 
ceramic/asphalt tile or linoleum.
Four (4) plastic anchors are provided along with three sizes  
(4 each) of #8 or #12 Phillips head screws for attaching the anti-
tip bracket to the floor. Use both the anchors and four (4) of the 
#8 screws when attaching the bracket to a concrete sub-floor. Do 
not use the anchors when attaching to a wood sub-floor.
1.  Determine the location of the range center line and front 
panel when the range is in its final position based on the 
Product Dimensions on page 4, and the actual cabinet/ 
cutout dimensions used for the installation.
2.  Determine the required position of the anti-tip bracket, 
based on the diagram on the facing page. Mark the four (4) 
mounting hole locations on the floor with a pencil.
3.  Determine the screw size required. The minimum full thread 
depth (portion of screw threaded into wood/slab) for wood 
is 3/8” (1 cm) and 5/8” (1.6 cm) for concrete. See the table 
below to select the correct screw size.
Sub-Floor Type/ 
Floor Covering Thickness
Screw Size
Concrete or wood sub-floor, no floor 
covering over top
#8 x 1” *
Concrete or wood sub-floor, floor 
covering up to 1/4” thick
#8 x 1” *
Concrete or wood sub-floor, floor 
covering over 1/4” and up to 1/2” thick
#8 x 1 1/4” *
Wood sub-floor, floor covering over 
1/2” and up to 1 3/16” thick
#12 x 1 3/4” *
Concrete sub-floor under floor covering  
over 1/2” thick
Must be purchased 
separately **
Wood sub-floor, floor covering  
over 1 3/16” thick
Must be purchased 
separately **
* Included with range
** Not included. Determine length based on step 3.
Attaching the bracket to a concrete floor:
• 
Drill four (4) 3/8” diameter countersink holes through any 
existing floor covering down to the concrete slab below. 
• 
Drill the 4 holes for the anchors 1 1/4” (3.2 cm) deep into the 
concrete slab using a 3/16” masonry bit. This hole length is 
longer than the anchor, but is required for proper installation. 
Clear the holes of dust and any other material. Tap each 
anchor into the hole until the anchor top is flush with the top 
of the concrete slab. Position the anti-tip bracket holes over 
the anchor holes. Insert the screws through the four (4) holes 
in the base of the bracket and thread them into the anchors. 
Be sure the screw threads fully engage the anchor body. 
Tighten the screws into place. 
Attaching the bracket to a wood floor:
• 
If there is ceramic, asphalt or other hard floor covering over 
the wood below, drill four (4) countersink holes to allow 
access to the wood below for drilling pilot holes.
• 
Drill four (4) pilot holes into the wood floor using a drill bit 
(1/16” dia. for #8 screws, 1/8” dia. for #12 screws). Position 
the anti-tip bracket holes over the holes in the floor. Insert the 
screws into the wood and tighten into place.
Installing the Anti-Tip Bracket on the Wall
1.  To use the wall mount option, the range front panel must not 
be more than 26 1/4” from the wall and the bracket screws 
must be able to thread into the base plate inside the wall 
behind. The notches on the sides of the bracket indicate the 
minimum required height of the base plate inside the wall and 
that any floor covering is not too thick for proper screw thread 
engagement.
Screws attached 
to sub-floor below 
floor covering
Sub-floor
Concrete 
anchors shown, 
do not use for 
wood sub-floor
Floor 
covering
Anti-tip 