Electrical & Installation requirements 
 
Electrical requirements 
IMPORTANT 
Observe all governing codes and ordinances. 
 
It is the customer’s responsibility: 
To contact a qualified electrical installer. 
To assure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 
— latest edition*, or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No.0-M91 - latest 
edition** and all local codes and ordinances. 
 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate. 
 
Do not ground to a gas pipe. 
Check with a qualified electrician if you are not sure range 
hood is properly grounded. 
Do not have a fuse in the neutral or ground circuit. 
 
IMPORTANT 
Save Installation Instructions for electrical inspector’s use. 
 
The range hood must be connected with copper wire only. 
 
The range hood should be connected directly to the fused 
disconnect (Or circuit breaker) box through metal electrical 
conduit.  
 
Wire sizes must conform to the requirements of the National 
Electrical Code ANSI/NFPA 70 — latest edition*, or CSA 
Standards C22.1-94, Canadian Electrical Code Part 1 and 
C22.2 No. 0-M91 - latest edition** and all local codes and 
ordinances. 
 
A U.L.- or C.S.A.-listed conduit connector must be provided 
at each end of the power supply conduit (at the range hood 
and at the junction box). 
 
Copies of the standards listed may be obtained from: 
 
* National Fire Protection Association Batterymarch Park Quincy, 
Massachusetts 02269 
 
** CSA International 8501 East Pleasant Valley Road Cleveland, 
Ohio 44131-5575 
 
Before installing the hood 
1.  For the most efficient air flow exhaust, use a straight run 
or as few elbows as possible. 
 
CAUTION:  Vent unit to outside of building, only. 
 
2.  At least two people are necessary for installation. 
 
3.  The hood is fitted with Screws and Drywall Anchors 
suitable for most surfaces, consult a Qualified Installer, 
check if they perfectly fit with your cabinet/wall. 
 
4.  Do not use flex ducting. 
 
5.  COLD WEATHER installations should have an additional 
backdraft damper installed to minimize backward cold air 
flow and a nonmetallic thermal break to minimize 
conduction of outside temperatures as part of the 
ductwork.  The damper should be on the cold air side of 
the thermal break.   
 
The break should be as close as possible to where the 
ducting enters the heated portion of the house. 
 
6.  Make up air: Local building codes may require the use of 
Make-Up Air Systems when using Ducted Ventilation 
Systems greater than specified CFM of air movement. 
 
The specified CFM varies from locale to locale. Consult 
your HVAC professional for specific requirements in your 
area.