 Figure 1:  Cabinet Clearances
For Electrical and Gas Supply Zone, see
Figure 3A.
Cooking
Surface
CAUTION:
See Figure 2
40"  Min. to
combustible
material
Ð
,
from cooking
surface
    as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current  Edition). *The range height is adjustable. The level
of the range top must be at the same level or above the
countertop level.
Range width
30" or 36"
30" or 36" Wide Hood
36" or 42" for Island
36" or 42" Wide Hood
42" or 48" for Island
}
}
For 30" Ranges
For 36" Ranges
Min. Distance Between Overhead  Cabinets  
of Combustible Material 
30" Range – 30"
36" Range  –  36"
13" Max.
Cabinet
Depth
}
10"  Min. to
combustible
side wall
material     ,
(both sides)
18"
Min.
*35-7/8" Min. Range Height
with Leveling Legs fully
retracted
*36-3/4" Max. Range Height
with Leveling Legs fully
extended.
30"  minimum from bottom of 
overhead Hood to cooking 
surface  (40" min.  if hood 
contains combustible 
materials       )