Gas and Electric Supply
Note:
If not already present, install gas shut-off valve in an easily 
accessible location. Make sure all users know where and 
how to shut off the gas supply to the range. 
Note:
The installer should inform the consumer of the location of 
the gas shut-off valve.
Note:
Any opening in the wall behind the appliance and any 
opening in the floor under the appliance must be sealed.
The gas ranges may be connected to the power supply 
with a range supply cord kit or by hard-wiring to the power 
supply. It is the responsibility of the installer to provide the 
proper wiring components (cord or conduit and wires) and 
complete the gas connection as dictated by local codes 
and ordinances, and/or the National Electric Code. The 
units must be properly grounded. Refer to Step 6 for 
details.
The range must be connected only to the type of gas 
for which it is certified.
 If the range is to be connected to 
propane gas, ensure that the propane gas supply tank is 
equipped with its own high pressure regulator in addition to 
the pressure regulator supplied with the range. (See 
Step 5.)
Note:
The range is designed for flush installation to the back wall. 
For a successful installation, it may be necessary to 
reposition the gas-supply line and electrical cord as the 
range is pushed back to its final position. 
SUGGESTION: This may be accomplished by carefully 
pulling on a rope or twine looped around the gas or 
electrical supply line as the range is pushed back into 
its final installed position. 
 Figure 3a: Gas & Electrical Supply Locations for All Gas Ranges
D
A
B
C
2-1/2"
30" (30" models)
36" (36" models)
2-1/2" maximum protrusion 
from wall for gas or 
electrical supply
Gas & Electrical 
Supply Zone
Model        A            B               C                D
   30” 
   5-3/4”     18-7/16”     5-13/16”    2-15/16”
   36” 
  8-1/16”   19-13/16”      8-1/8”       3-3/16”