Dacor ERV48ER Installationsanweisungen

Seite von 16
10
Ground
Power Input
Blower Output
Installation Instructions
Electrical Access 
Panel
ERV Electrical 
Access Panel
ERV Raised Vent  
Front View
To power conduit
Connect other end of 
wires to remote blower 
terminal block
Wires to power plug 
Pre-wired at factory 
Do not modify
Attach ground wire 
as shown
Match wire colors to 
terminals as shown
BLACK
WHITE
GREEN
Electrical Installation
 WARNING
ELECTRIC SHOCK HAZARD - Do not connect power to 
the unit until installation is complete.
Run the conduit line used to supply power from the 
1. 
raised vent to the remote blower parallel to the duct 
work.
Make sure the raised vent power plug is disconnected 
2. 
from the electrical outlet.
Remove the cover from the raised vent electrical 
3. 
access panel. 
Connect the conduit to the remote blower as shown in 
4. 
the wiring diagrams on this page and the facing page.
Replace the electrical access panel.
5.