Gaggenau AW442720 Installationsanleitung

Seite von 60
16
Extraction mode unit with internal remote fan unit 
AR 400 743
1
Attach the exhaust air pipe directly to the remote 
fan unit’s air pipe connector 
(A)
.
2
Connect it to the air extractor opening 
(B)
.
3
Seal the joints appropriately.
Extraction mode units without internal remote fan unit 
AR 400 743
1
Unscrew the connecting pieces from the cover 
plate in the ventilation hood. Secure the exhaust air 
pipe to the connecting piece. Screw the connecting 
piece to the cover plate in the ventilation hood.
2
Connect it to the air extractor opening.
3
Seal the joints appropriately.
Connecting the power supply
1
Plug the mains plug into the grounded socket.
2
If a fixed connection is required, please follow the 
instructions in the 
Electrical Connection
 section.
Attaching flue duct
9
WARNING
Risk of injury
Components inside the appliance may have sharp 
edges. Wear protective gloves.
1
Remove the protective foil from both flue ducts.
2
Fit the upper flue duct. 
Hook both side panels onto the angle brackets and 
screw them in at both sides. 
$5
$
%