30" GAS RANGE INSTALLATION INSTRUCTIONS
Clearances and dimensions
1. 
Location—Check location where the range will be installed. Check for proper electrical and gas supply, and the 
stability of floor.
2. 
dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface 
must be solid and level.
*  30" minimum clearance between the top of 
the cooking surface and the bottom of an 
unprotected wood or metal cabinet; or 24" 
minimum when bottom of wood or metal 
cabinet is protected by not less than ¼" flame 
retardant millboard covered with not less than 
no. 28 MSG sheet steel, 0.015" stainless 
steel, 0.024" aluminum or  0.020" copper. 
The minimum clearance is 0" for the rear of 
the range. Follow all dimension requirements 
provided above to prevent property damage, 
potential fire hazard, and incorrect countertop 
and cabinet cuts.
Avoid locating cabinet storage space 
above the surface burners to eliminate 
the possibility of cabinets catching on 
fire, or personal burns from reaching 
for the cabinets over the heated units. If 
cabinet storage is to be provided, risk can 
be reduced by installing a range hood 
that projects horizontally a minimum of 5" 
beyond the bottom of the cabinets.
Special instructions for appliances installed in the state 
of Massachusetts: This Appliance can only be installed 
in the state of Massachusetts by a Massachusetts 
licensed plumber or gas fitter. When using a flexible 
connector, it must not exceed three (3) feet (36 in.) long. 
A "T" handle type manual gas valve must be installed in 
the gas supply line to this appliance.
Installation beside wall
If installing beside a wall, the minimum distance to 
combustible wall on either side of range above 36” 
height.
Figure 1
Figure 2
*5”
Figure 3
30”
46”
Door open
49”
Max.
36 ±
1
/
8
29 
7
/
8
25 ¾”