Frigidaire FGGF304DPF Installationsanweisungen
2
30" GAS RANGE INSTALLATION INSTRUCTIONS
Clearances and dimensions
1.
Location—Check location where the range will be installed. Check for proper electrical and gas supply, and the
stability of floor.
stability of floor.
2.
dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface
must be solid and level.
must be solid and level.
* 30" minimum clearance between the top of
the cooking surface and the bottom of an
unprotected wood or metal cabinet; or 24"
minimum when bottom of wood or metal
cabinet is protected by not less than ¼" flame
retardant millboard covered with not less than
no. 28 MSG sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
The minimum clearance is 0" for the rear of
the range. Follow all dimension requirements
provided above to prevent property damage,
potential fire hazard, and incorrect countertop
and cabinet cuts.
unprotected wood or metal cabinet; or 24"
minimum when bottom of wood or metal
cabinet is protected by not less than ¼" flame
retardant millboard covered with not less than
no. 28 MSG sheet steel, 0.015" stainless
steel, 0.024" aluminum or 0.020" copper.
The minimum clearance is 0" for the rear of
the range. Follow all dimension requirements
provided above to prevent property damage,
potential fire hazard, and incorrect countertop
and cabinet cuts.
Avoid locating cabinet storage space
above the surface burners to eliminate
the possibility of cabinets catching on
fire, or personal burns from reaching
for the cabinets over the heated units. If
cabinet storage is to be provided, risk can
be reduced by installing a range hood
that projects horizontally a minimum of 5"
beyond the bottom of the cabinets.
Special instructions for appliances installed in the state
of Massachusetts: This Appliance can only be installed
in the state of Massachusetts by a Massachusetts
licensed plumber or gas fitter. When using a flexible
connector, it must not exceed three (3) feet (36 in.) long.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
in the state of Massachusetts by a Massachusetts
licensed plumber or gas fitter. When using a flexible
connector, it must not exceed three (3) feet (36 in.) long.
A "T" handle type manual gas valve must be installed in
the gas supply line to this appliance.
Installation beside wall
If installing beside a wall, the minimum distance to
combustible wall on either side of range above 36”
height.
Figure 1
Figure 2
*5”
Figure 3
30”
46”
Door open
49”
Max.
36 ±
1
/
8
”
29
7
/
8
”
25 ¾”