Frigidaire FGEF306TPF Installationsanweisungen

Seite von 24
2
30" ELECTRIC RANGE INSTALLATION INSTRUCTIONS
1.  Clearances and dimensions
a. Provide adequate clearances between the range and adjacent combustible surfaces.
b.  Location—Check location where the range will be installed. Check for proper electrical supply and the stability of floor.
c. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must 
be solid and level.
*  30" (76,2 cm) minimum clearance between the top of 
the cooking surface and the bottom of an unprotected 
wood or metal cabinet; or 24" (61 cm) minimum when 
bottom of wood or metal cabinet is protected by 
not less than ¼" (0,6 cm) flame retardant millboard 
covered with not less than no. 28 MSG sheet steel, 
0,015" (0,04 cm) stainless steel, 0,024" (0,06 cm) 
aluminum or 0,020" (0,05 cm) copper. The minimum 
clearance is 0" (0 cm) for the rear of the range. Follow 
all dimension requirements provided above to prevent 
property damage, potential fire hazard, and incorrect 
countertop and cabinet cuts.
Avoid locating cabinet storage space above the 
surface units to eliminate the possibility of cabinets 
catching on fire, or personal burns from reaching for 
the cabinets over the heated units. If cabinet storage 
is to be provided, risk can be reduced by installing a 
range hood that projects horizontally a minimum of 
5" (12,7 cm) beyond the bottom of the cabinets.
fRONT
vIeW
bACK
vIeW
Wall 
edge
All dimensions 
for electrical 
outlet location 
are maximum.
Cubed area shows 
where the electrical 
outlet must be 
installed for the range 
to be flush to the wall.
Terminal 
block 
Location
C : Center Line
L