Whirlpool WEC530H0DB Installationsanweisungen

Seite von 32
14
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3 N-m)
3. Use 
³⁄₈" nut driver to connect the bare (green) ground wire to 
the center terminal block post with one of the 10–32 hex nuts.
4. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
5. Firmly tighten hex nuts.
IMPORTANT: Verify the tightness of the hex nuts.
6. Replace lower access cover.
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes 
Recreational vehicles
In an area where local codes prohibit grounding through the 
neutral
1. Part of metal ground strap must be cut out and removed.
2. Use a Phillips screwdriver to remove the ground-link screw 
from the back of the range. Save the ground-link screw and 
the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range. 
Allow enough slack to easily attach wiring to the terminal 
block.
Wire Awg
Torque
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 lbs-in. (4.0 N-m)
A. 10–32 hex nut
B. Line 2 (red)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 1 (black)
F. Terminal lug
B
F
A
E
D
C
A. Metal ground strap
B. Discard
C. Ground-link screw
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Bare (green) ground wire
E. Line 2 (red) wire
F. Neutral (white) wire
G. Line 1 (black) wire
A
B
C
A
B
C
D
E
G
F