5. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the 10–32 hex nuts.
6. Connect line 2 (red) and line 1 (black) wires to the outer 
terminal block posts with 10-32 hex nuts.
7. Firmly tighten hex nuts.
NOTE: For power supply cord replacement, use only a power 
cord rated at 250 volts minimum, 40- or 50-amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
8. Tighten strain relief screws.
IMPORTANT: Verify the tightness of the hex nuts.
9. Replace lower access cover.
Install Using Direct Wire
Direct wire strain relief
1. Disconnect power.
2. Remove the lower access cover screws located on the back 
of the range. Pull the bottom of the cover toward you and out 
to remove cover from range. 
3. Remove plastic tag holding three 10-32 hex nuts from the 
middle post of the terminal block.
4. Assemble a UL listed conduit connector in the opening.
5. Tighten strain relief screw against the flexible conduit.
A. 10–32 hex nut
B. Ground-link screw
C. Line 2 (red)
D. Green ground wire
E. Neutral (center) wire 
F. Line 1 (black)
A
B
C
F
D
E
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
A. Three mounting tabs
B. Lower access cover
C. Screws (2)
A. Removable retaining nut
B. Conduit
A
B
C
A
B