3-wire Direct Wire Connection
Use where local codes permit connecting cabinet-ground 
conductor to neutral wire. 
B
5.
 
Remove center screw
Remove center terminal block screw (B).
Direct wire cable must have 5 ft. (1.52 m) of extra length so 
dryer may be moved if needed.
Strip 3
1
/
2
" (89 mm) of outer covering from end of cable. Strip 
insulation back 1" (25 mm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape wire ends 
into hooks. 
     1"
(25 mm)
    3½"
(89 mm)
3.
 
Prepare your 3-wire cable for  
 
direct connection
To connect wires to terminal block, place hooked end of wire  
under terminal block screw, facing to the right, squeeze 
hooked end together and tighten screw.
4.
 
Connect wires to terminal block
1.
 
Prepare to connect neutral 
 
ground wire and neutral wire
B
A
E
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Optional 3-wire Connection
You must verify with a qualified electrician that this grounding 
method is acceptable before connecting.
Connect remaining wires
7.
Place hooked ends of remaining direct wire cable wires under 
outer terminal block screws (hooks facing right). Squeeze 
hooked ends together and tighten screws. Finally, reinsert 
tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw. Now, go to Venting 
Requirements.
B
C
Place hooked end of neutral wire (white or center) (C) of direct 
wire cable under center terminal block screw (B). Squeeze 
hooked end together. Tighten screw.
6.
 
Connect neutral wire