Maytag MEDX6STBW Installationsanweisungen

Seite von 20
13
B
C
E
Connect neutral ground wire 
and neutral wire
2. 
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center 
terminal block screw (B). Tighten screw.
Venting Requirements
Venting
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent 
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal 
block screws (hooks facing right). Tighten screws. 
A
E
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external 
ground conductor screw (A) to an adequate ground. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. Now, go to 
Venting Requirements. 
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: 
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
 
Only a 4" (102 mm) heavy metal exhaust vent and clamps may 
be used. 
 
Do not use plastic or metal foil vent.
Rigid metal vent:
 
Recommended for best drying performance and to avoid 
crushing and kinking.
Flexible metal vent: 
(Acceptable only if accessible to 
clean)
 
Must be fully extended and supported in final dryer location.
 
Remove excess to avoid sagging and kinking that may result 
in reduced airflow and poor performance.
 
Do not install in enclosed walls, ceilings, or floors.
 
The total length should not exceed 7
3
/
4
 ft. (2.4 m).
NOTE: 
If using an existing vent system, clean lint from entire 
length of the system and make sure exhaust hood is not plugged 
with lint. Replace plastic or metal foil vents with rigid metal 
or flexible metal vents. Review “Vent System Chart” and, if 
necessary, modify existing vent system to achieve best drying 
performance.