Samsung DV400EWHDWR/ Benutzeranleitung

Seite von 12
4
Data Display Mode
Definition of Temperature Display Mode:
Display Mode 0 : Temperature data(Celsius)
Display Mode 1 : Average Touch Sensor data for 1 minute
Display Mode 2 : Average Temperature(Celsius) data for 1minute 
How to Enter:
With Power On, press AdjustUp Key + AdjsutDown Key for 7 seconds until it sends out a 
beeping sound .
If not pressed any keys for 5 minutes, it will be set back from Data Display Mode
If pressing AdjustUp Key in this mode ,Display Mode ID will be increased.
If pressing AdjustDown Key in this mode ,Display Mode ID will be decreased.
• Converting °C  °F
Celsius(°C)
-30
-10
10
30
50
70
F =9/5C + 32
Fahrenheit(°F)
-22
14
50
86
122
158
System Check Mode
Definition of System Check Mode:
“ t2 ” will display.
System Check Mode(t2 mode) Progress Function Performed Start/Pause  
Motor(CW) Relay On  Heater Relay On  Heater Relay Off,  Motor(CW) Relay Off
How to Enter:
While in Power Off, pressing the Dry Level + Power keys simultaneously will put the dryer into 
the System Check mode
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before 
servicing, unless testing requires power.
[HUDSON]_Technical_information-03171A_EN.indd   4
2012-02-03   �� 5:01:21