U-Line Wine Captain Dual Zone 43 Bottle Wine Cellar - Integrated Frame Glass Door - Right Hand Hinge Benutzerhandbuch

Seite von 46
USER GUIDE
 Troubleshooting 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Troubleshooting
BEFORE CALLING FOR SERVICE
If you think your U-Line product is malfunctioning, read 
the CONTROL OPERATION section to clearly understand 
the function of the control.
If the problem persists, read the NORMAL OPERATING 
SOUNDS and TROUBLESHOOTING GUIDE sections below 
to help you quickly identify common problems and 
possible causes and remedies. Most often, this will resolve 
the problem without the need to call for service. 
IF SERVICE IS REQUIRED
If you do not understand a troubleshooting remedy, or 
your product needs service, contact U-Line Corporation 
directly at +1.800.779.2547.
When you call, you will need your product Model and 
Serial Numbers. This information appears on the Model 
and Serial number plate located on the upper right or rear 
wall of the interior of your product. 
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to 
provide high thermal efficiency and maximum sound 
reduction for its internal working components. Despite this 
technology, your model may make sounds that are 
unfamiliar. 
Normal operating sounds may be more noticeable because 
of the unit’s environment. Hard surfaces such as cabinets, 
wood, vinyl or tiled floors and paneled walls have a 
tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a 
brief description of the normal operating sounds they 
make. NOTE: Your product may not contain all the 
components listed.
• Compressor: The compressor makes a hum or pulsing 
sound that may be heard when it operates. 
• Evaporator: Refrigerant flowing through an evaporator 
may sound like boiling liquid. 
• Condenser Fan: Air moving through a condenser may 
be heard.
• Automatic Defrost Drain Pan: Water may be heard 
dripping or running into the drain pan when the unit is 
in the defrost cycle.
TROUBLESHOOTING GUIDE
DANGER
!
ELECTROCUTION HAZARD. Never attempt to 
repair or perform maintenance on the unit 
before disconnecting the main electrical power.
Troubleshooting - What to check when problems occur:
Problem
Possible Cause and Remedy
Digital Display 
and Light Do Not 
Work.
Ensure power is connected to the unit.
If the unit is cooling, it may be in Sabbath 
mode.
Interior Light 
Does Not 
Illuminate.
The light bulb may be defective.
If the unit is cooling, it may be in Sabbath 
mode. 
Light Remains on 
When Door Is 
Closed.
For glass door models, press the light icon 
and close the door.
Check reed switch.
Unit Develops 
Frost on Internal 
Surfaces.
Frost on the rear wall is normal and will melt 
during each off cycle. 
If there is excessive build-up of 1/4" or 
more, manually defrost the unit. 
Ensure the door is closing and sealing 
properly. 
High ambient temperature and excessive 
humidity can also produce frost. 
Unit Develops 
Condensation on 
External 
Surfaces.
The unit is exposed to excessive humidity. 
Moisture will dissipate as humidity levels 
decrease.
Digital Display 
Functions, But 
Unit Does Not 
Cool.
Ensure the unit is not in “Showroom Mode.”
Momentarily unplug or interrupt power 
supply to the unit.
Digital Display 
Shows ER or E 
Followed by a 
Number.
E3 indicates the door may be opened too 
long. Ensure the door is closing properly. 
For other error codes contact U-Line 
Customer Service.