U-Line Wine Captain Dual Zone 43 Bottle Wine Cellar - Integrated Frame Glass Door - Right Hand Hinge Benutzerhandbuch

Seite von 46
USER GUIDE
 Troubleshooting 2
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
CHECKING PRODUCT TEMPERATURE
To check the actual product temperature in the 
unit:
1. Partially fill a plastic (nonbreakable) bottle with water. 
2. Insert an accurate thermometer. 
3. Tighten the bottle cap securely.
4. Place the bottle in the desired area for 24 hours. 
5. Avoid opening the unit during the testing period. 
6. After 24 hours, check the temperature of the water. If 
required, adjust the temperature control in a small 
increment (see CONTROL OPERATION). 
Causes which affect the internal temperatures of 
the cabinet include:
• Temperature setting.
• Ambient temperature where installed.
• Installation in direct sunlight or near a heat source.
• The number of door openings and the time the door is 
open.
• The time the internal light is illuminated. (This mainly 
affects product on the top rack or shelf.) 
Digital Display 
Shows 1-16 or 99
A factory test mode may be enabled. Adjust 
the temperature to 99 and press the LIGHT 
icon.
Product Is 
Freezing.
Because product in contact with the rear 
wall may freeze, ensure no product is 
touching the rear wall. 
Adjust the temperature to a warmer set 
point.
Product Is Not 
Cold Enough.
Air temperature does not indicate product 
temperature. See CHECKING PRODUCT 
TEMPERATURE below.
Adjust the temperature to a cooler set point.
Ensure unit is not located in excessive 
ambient temperatures or in direct sunlight.
Ensure the door is closing and sealing 
properly.
Ensure the interior light has not remained 
on too long.
Ensure nothing is blocking the front grille, 
found at the bottom of the unit.
Ensure the condenser coil is clean and free 
of any dirt or lint build-up.
Problem