Printer Operation
Menu Setting Table
Page Setup Menu - allows you to change settings related to the media or print quality.
System Setup Menu - allows you to change settings for the printer hardware and basic control systems.
After Print Menu - changes how the printer reacts after the label has been printed.
Interfaces - changes interface parameters such as baud rate.
Machine Information, Test Mode - allows you to check and/or print test pages and information about the printer.
Global Config menu - allows you to switch between 3 complete ‘config sets’ contained within the printer.
Menu Setting
Press the MENU key in print possible status to enter MENU Setup Mode. Use the keys on the operation panel
according to the LCD display to setup the printer. The contents that can be setup on the printer are shown
below. And the items that are actually displayed on the LCD are shown in [  ].
7 Datamax Emulation
Top Menu
Sub Menu
Default
Menu
Remarks
Page Setup
Print Speed
7 IPS
2 to 10 IPS
Printing speed setting.
Print Darkness
12
00 to 30
Adjusting print darkness.
Darkness Adjust
00
-10 to 10
Fine adjustment of darkness commands.
[Darkness Adj]
Print Method
TT
TT (Thermal Transfer) Selection of Thermal Transfer (ribbon) or
DT (Direct Thermal)
Direct Thermal.
Continuous Media
4.00 inch
0.25 to 32.00 inch
Setting media length of continuous media.
Length
101.6 mm
6.4 to 812.8 mm
Lower level = during mm mode.
[Cont Media Len]
Vertical Position
0.00 inch
-1.00 to 1.00 inch
Adjusting printing start position.
[Vertical Pos]
0.0 mm
-25.4 to 25.4mm
Horizontal Shift
0.00 inch
-1.00 to 1.00 inch
Adjusting horizontal image position.
[Horizontal Shif]
0.0 mm
-25.4 to 25.4mm
Vertical Image Shift
0.00 inch
0.00 to 32.00 inch
Adjust the off set value in vertical when
[Vertical Image]
0.0 mm
0.0 to 812.8mm
mapping data on the printer RAM.
Sensor Select
Rear Adj Sensor Rear Adj Sensor
Selecting front fixed/rear adj. sensor.
Front Fixed Sen
Media Sensor
See Through
See Through
Selecting media sensor.
Reflect
None
Small Media
Off
On
Setting for small media.
Adjustment
Off
[Small Media Adj]
Small Media
1.00 inch
0.25 to 1.00 inch
Setting media length for small media.
Length
25.4 mm
6.4 to 25.4mm
[Small Media Len]
Symbol Set
PM
50 symbols
Setting symbol set.
System Setup
Sensor Monitor
Displays level of sensor that is currently
selected.
Sensor Level
1.4 V
0.0 V to 3.0 V
Selects threshold of the sensor.
Paper End Level
2.80 V
0.01 V to 3.00 V
Sets the paper end level.
Cover Open Sensor
Off
On
Sets the cover open sensor.
[Cover Sensor]
Off
Buzzer Select
Exec/Err
Exec/Err
Setting buzzer sounding conditions.
All
Error
Key
None
Mode Settings
[Datamax Emulation]