VENT INSTALLATION 
Always maintain minimum clearances around vent systems. The minimum clearances 
to combustibles for horizontal vent pipe are 3" at the top and 1" at the sides and bottom 
of the vent system until the pipe penetrates the nearest vertical wall. A 1" minimum 
clearance all around the pipe must be maintained. Do not pack the open air spaces with 
insulation or other materials. This could cause high temperatures and may present a 
fire hazard.
W
ARNING
Figure 16 - Horizontal Vent Termination Location
Vent Terminal
Air Supply Inlet
Area Where Terminals Not Permitted
Inside Corner Detail 
FOR HORIZONTAL TERMINATION
MINIMUM DISTANCES 
A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305mm) minimum].   
B = Clearance to window or door that may be opened [*12" (305mm) minimum]. 
C = Clearance  to  permanently  closed  window  [*minimum  12"  (305mm)  recommended  to  prevent  condensation  on 
window]    
D
 
= Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two (2) feet (610mm) 
from the centerline of the terminal [18" (457mm) minimum].  
E
 
=  Clearance to unventilated soffits [12" (305mm) minimum]. Clearance to vinyl soffit [30" (762mm)]. 
F =  Clearance to an outside corner. See page 14.  
G = Clearance to an inside corner. See page 14.  
H = *Not to be installed above a gas meter/regulator assembly within three (3) feet (914mm) horizontally from the centerline 
of the regulator. 
I =  Clearance to service regulator vent outlet [*3' (914mm) minimum]. 
J =  Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [*12" 
(305mm)minimum]. 
K = Clearance to a mechanical air supply inlet [*6' (1829mm) minimum]. 
L
 
=  Clearance above a paved sidewalk or paved driveway located on public property [
**
7' (2133mm) minimum]. 
M
 
= Clearance under veranda, porch, deck, or balcony [*12" (305mm) minimum
***
].
N = Clearance above a roof shall extend a minimum of 24" (610mm) above the highest point when it passes through the roof 
surface and any other obstruction within a horizontal distance of 18" (457mm). 
*  As  specified  in  CAN/CGA  B149  Installation  Codes.  Note:  Local  codes  or  regulations  may  require  different 
clearances. 
**  A vent must not terminate directly above a sidewalk or paved driveway, which is located between two single-family 
dwellings and serves both dwellings. 
 
*** Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.