Monessen Hearth 6000DV Benutzerhandbuch

Seite von 52
20 
42D0200
V
G
G=6" (152mm)
F
F=6" (152mm)
V
V
G
G = Combustible 24"(610mm)
Noncombustible 18"(457mm)
Combustible &
Noncombustible
H = 24" (610mm)
J = 20" (508mm)
V
H
J
C = Maximum depth of 48" (1219mm)
for alcove location
D = Minimum width for back wall of
alcove location
Combustible - 38" (965mm)
Noncombustible - 24" (610mm)
E = Clearance from corner in alcove
location
Combustible - 6" (152mm)
Noncombustible - 2" (51mm)
E
V
D
C
C
Inside Corner
Alcove Location
Outside Corner
Balcony with No Side Wall
Balcony with Perpendicular
Side Wall
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
2 4 6 8 10 1214 16 1820
eg: A
VENT INSTALLATION 
TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE  
AND NONCOMBUSTIBLE EXTERIORS 
Figure 17 - Allowable Venting Chart 
HOW TO USE THE VENT GRAPH
The Vent Graph should be read in conjunction with the following 
vent installation instructions to determine the relationship between 
the vertical and horizontal dimensions of the vent system.
1.   Determine the height of the center of the horizontal vent pipe 
exiting through the outer wall. Using this dimension on the 
Sidewall Vent Graph below, locate the point intersecting with 
the slanted graph line.
2.   From the point of this intersection, draw a vertical line to the 
bottom of the graph.
3.   Select the indicated dimension, and position the fireplace in 
accordance with same.
 
Example: If the vertical dimension from the floor of the 
fireplace is 11' (3.4m) the horizontal run to the face of the 
outer wall must not exceed 14' (4.3m).
 
Example: If the vertical dimension from the floor of the unit 
is 7’ (2.14m), the horizontal run to the face of the outer 
wall must not exceed 8
1
/
2
' (2.6m).
Sidewall Vent Graph showing the relationship between vertical and 
horizontal dimensions for a Direct Vent flue system.
Figure 18 - Rear Wall Venting Graph
Horizontal Dimension From the Outside Face of the Wall 
to the Center of the Fireplace Vent Flange
V
ertical Dimension From the Floor of Unit to the Center of the 
Horizontal V
ent Pipe
Dimensions in 
Feet
20"