Component Identification
312796R
7
Grounding
See F
. 2. Verify that the ground screw (GS) is 
attached and tightened securely to the air motor. Con-
nect the other end of the ground wire (U) to a true earth 
ground.
Accessories
Bleed-type master air valve
Required in your system to relieve air trapped 
between it and the air motor when the valve is 
closed.
Be sure the valve is easily accessible from the 
pump and located downstream from the air regula-
tor.
Air regulator
Adjusts air pressure to the motor and fluid outlet pres-
sure of pump. Locate it close to the pump. Install a 
gauge to read air pressure.
Air filter
Removes harmful dirt and moisture from compressed air 
supply.
F
IG
. 2: Ground wire
GS
U
ti12914a
Trapped air can cause the pump to cycle unexpectedly, 
which could result in serious injury from splashing or 
moving parts.