Graco M18xxx Benutzerhandbuch

Seite von 26
Troubleshooting 
8
312796R
Troubleshooting
Relieve the pressure before checking or servicing 
the equipment.
NOTICE
Check all possible problems and causes before dis-
assembling the pump.
Problem
Cause
Solution
Air motor will not run.
DataTrak solenoid engaged (DataTrak 
models with runaway protection).
Push solenoid release button (118).
Remove solenoid and manually 
move pin.
Damaged air valve (17). 
Replace or service air valve (17). 
See page 9.
Damaged pilot valve (19).
Replace pilot valves (19). See page 
13.
Air continuously exhausting 
around air motor piston rod.
Damaged u-cups (3, 43).
Replace piston rod u-cups (3, 43). 
See page 13.
Air continuously exhausting from 
muffler.
Damaged air valve plate (105) or cup 
(112).
Replace or service air valve (17). 
See page 9.
Air motor “bounces” at top of 
stroke.
Damaged bottom pilot valve.
Replace bottom pilot valve (19). See 
page 13.
Air motor “bounces” at bottom of 
stroke.
Damaged top pilot valve.
Replace top pilot valve (19). See 
page 13.
Icing inside motor.
Air motor operating at high pressure 
or high cycle rate.
Reduce pressure, cycle rate, or duty 
cycle of motor.
Reduce dew point of compressed air 