KitchenAid 1954 Installationsanweisungen

Seite von 32
by  tightening  the  joint,  or  unscrewing  completely  and 
applying  additional  pipe  dope  and  re-tightened.  Any 
factory  connections  which  may  have  been  disturbed 
should be retested.
a match should never be used when testing for leaks. 
all  fittings  have  been  tightened  and  tested  at  the 
factory. if a leak is detected, tighten the fitting. Don’t 
use pipe dope on factory fittings.
range toP conVersion to “lP”
models 1955 & 1956
All  our  ranges  are  factory  set  to  burn  natural  gas  unless 
“LP” is specified. To use the range on “LP” gas, please do 
the following:
order an “lP” kit from the factory. $35 UPS included.
Burner 
large 
medium 
small 
Nat. Gas 
#50 (1.75 mm)  #55 (1.32 mm)  #57 (1.09 mm) 
LP/Propane  #64 (.91 mm) 
#65 (.89 mm) 
#70 (.71 mm)
Store  natural  gas  spuds  so  they  are  available  for  future 
conversions.
installation of “lP” spuds
Apply  masking  tape  to  the  end  of  a  7  mm  nut  driver  to 
help  hold  the  gas  orifice  spud  in  the  nut  driver  while 
changing  it.  Press  nut  driver  down  onto  the  gas  orifice 
spud  and  remove  by  turning  it  counterclockwise  and 
lifting out, set gas orifice spud aside.
Gas orifice spuds are stamped with a number on the side. 
Replace  the  LP  gas  orifice  spud  with  the  correct  Natural 
gas orifice spud.
Refer  to  the  following  chart  for  the  correct  Natural  gas 
orifice spud placement.
conversion of regulator to “lP”  
on model 1955 
Disconnect Power to range
•  Open oven door and remove it, see removal instructions 
on page 16. 
•  With a Philips driver, undo the 2 screws holding the top 
down.
•  Pull  top  forward  about  2”  then  lift  front.  Raise  the 
service stay on each side to hold the top up.
•  On the back right of the range unscrew the nut on top of 
the regulator.
•  Reverse the white insert pin by pulling it out of the cap, 
reverse  it,  then  snap  it  back  into  the  cap.  Replace  cap 
into  body  of  regulator  and  tighten,  making  sure  not  to 
disturb the regulator spring.
Figure 13 
Nat. Gas 
LP Gas
replacing rangetop orifices
Tools required to replace orifices. 
Small adjustable wrench.
1. Remove the lift off burner cap.
2.  With  the  small  adjustable  wrench,  unscrew  the  brass 
venturi and remove.
3.  Unscrew  the  natural  gas  orifices  in  each  of  the  top 
burners using the 7mm nut driver included with orifice 
kit. Replace with “LP” orifices listed below.
 
 
nat. gas 
lP/Propane 
Front left superburner takes 
1.75 mm (#50)  .91 mm (#64)  
Other front burners take 
1.32 mm (#55)  .89 mm (#65) 
All rear burners use 
1.09 mm (#57)  .71 mm (#70)
Note: example. Orifices are stamped metric sizes. (00) is 
the number drill equivalent.
4.  Reinstall the brass 
venturi.
Store  nat.  gas  orifices 
and  nut  driver  so  they 
are  available  for  future 
conversions.
When  replacing  the 
black  caps,  make  sure 
that  the  tabs  in  the  cap 
fit  into  the  grooves  of 
the burner base.
12