Bertazzoni X)486GPIRVI Benutzerhandbuch

Seite von 52
 
9
BEFORE INSTALLATION  
This appliance shall only be installed by an 
authorized professional.  
This appliance shall be installed in accordance 
with the manufacturer’s installation instructions. 
This appliance must be installed in accordance 
with the norms & standards of the country where 
it will be installed. The installation of this 
appliance must conform to local codes and 
ordinances. In the absence of local codes, 
Installations must conforms to American National 
Standards, National Fuel Gas Code ANSI Z223.1 – 
latest edition** or B149.1.
 
The appliance, when installed, must be 
electrically grounded in accordance with local 
codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70. 
If local codes permit, a flexible metal appliance 
connection with the new AGA or CGA certified 
design, max. 5 feet (1,5 m) long, ½” I.D. is 
recommended for connecting this appliance to 
the gas supply line. Do not bend or damage the 
flexible connector when moving the appliance.  
This appliance must be used with the pressure 
regulator provided. The regulator shall be 
properly installed in order to be accessible when 
the appliance is installed in its final location. The 
pressure regulator must be set for the type of gas 
to be used. The pressure regulator has ½” female 
pipe thread. The appropriate fitting must be 
determined based on the size of your gas supply 
line, the flexible metal connector and the shutoff 
valve. 
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shutoff valve during any pressure  testing 
of the gas supply piping  system  at test pressures 
equal to or less than ½ psi (3.5 kPa). 
All opening and holes in the wall and floor, back 
and under the appliance shall be sealed before 
installation of the appliance. 
A manual valve shall be installed in an accessible 
location in the gas line external to the appliance 
for the purpose of turning on or shutting off gas 
to the appliance 
 
WARNING! 
Do not use aerosol sprays in the vicinity of this 
appliance while it is in operation 
ROOM VENTILATION: An exhaust fan may be 
used with the appliance; in each case it shall be 
installed in conformity with the appropriate 
national and local standards. Exhaust hood 
operation may affect other vented appliances; in 
each case it shall be installed in conformity with 
the appropriate national and local standards. 
 
TYPE OF GAS 
This appliance is shipped from the factory for use 
with natural gas. For use with propane LP gas 
please follow the conversion procedure 
described on pg. 17. A step by step conversion 
procedure is also included with each set of LP gas 
nozzles.  
 
GAS PRESSURE 
The maximum inlet gas supply pressure incoming 
to the gas appliance pressure regulator is 20’’ 
water column (5 kPa) . 
The minimum gas supply pressure for checking 
the regulator setting shall be at least 1“ w.c. (249 
Pa) above the inlet specified manifold pressure to 
the appliance (this operating pressure is 4” w.c.     
(1.00 kPa) for Natural Gas and 11” w.c. (2.75 kPa  
for LP Gas).