Hoshizaki KML-200MAE Betriebsanweisung

Seite von 51
13
2nd Cycle and after with pump drain
IMPORTANT
Freeze cycle time is limited to 60 minutes
even if Float Switch does not open.
1. Float Switch opens and signals to complete
    freeze cycle.
    10/20 second Drain Timer starts counting.
3. Thermistor reads 48° F.
    Defrost Timer (adjustable
    from 1 to 3 minutes) starts
    counting.
IMPORTANT
Water Valve
opening is limited
to 6 minutes.
2. Drain Timer stops counting.
    Pump drain is completed
4. Defrost Timer stops counting.
    Defrost cycle is completed and freeze cycle
    starts.
IMPORTANT
1. Board never accepts defrost completion
    signal within the first 2 minutes in defrost
    cycle.
2. Defrost cycle time is limited to 20 minutes
    even if Defrost Timer does not stop counting.
5. After the first 5 minutes in freeze cycle.
    Ready to complete freeze cycle when Float
    Switch circuit opens.
IMPORTANT
Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.
,
& LINE VALVE