Hoshizaki KML-200MAE Betriebsanweisung

Seite von 51
14
IMPORTANT
Freeze cycle time is limited to 60 minutes
even if Float Switch does not open.
2nd Cycle and after with no pump drain
1. Float Switch opens and signals to complete
    freeze cycle.
4. After the first 5 minutes in freeze cycle.
    Ready to complete freeze cycle when Float
    Switch circuit opens.
3. Defrost Timer stops counting.
    Defrost cycle is completed and freeze cycle
    starts.
IMPORTANT
Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.
IMPORTANT
1. Board never accepts defrost completion
    signal within the first 2 minutes in defrost
    cycle.
2. Defrost cycle time is limited to 20 minutes
    even if Defrost Timer does not stop counting.
IMPORTANT
Water Valve
opening is limited
to 6 minutes.
2. Thermistor reads 48° F.
    Defrost Timer (adjustable from
    1 to 3 minutes) starts counting.