Dacor MCS130 Benutzerhandbuch

Seite von 16
5
i
nsTallaTion
 s
peCifiCaTions
Verify that all required components have been provided. If 
any item is missing or damaged, please contact your dealer 
immediately. Do not install a damaged or incomplete appliance.
•  Mounting Screws 
•  Use and Care Videotape
•  Oven Racks
•  Broiler Grill and Pan
•  Exhaust Grill/Lower Trim
•  Rear Top Trim
•  GlideRack™ Oven Rack
•  Light Lens Pry Stick
A qualified technician must complete the installation of this built-in 
appliance. Proper installation is your responsibility.
Carefully check the location where the oven is to be installed. The 
oven should be placed for convenient access. Make certain that 
electrical power can be provided in the selected location.
Plan the installation so that all minimum clearances are met or 
exceeded. Dimensions shown provide minimum clearances, 
unless otherwise noted. Be certain that proper clearance is 
provided for the oven door when it is in the open position.
The specified minimum cabinet depth and width must be provided. 
The cabinet depth and width must completely enclose the 
recessed portion of the oven.
Cabinet cutout dimensions must be used as indicated. All contact 
surfaces between the appliance and the cabinet must be solid and 
level. The oven support platform must be flush with the bottom 
edge of the cabinet cutout.
Make certain that you have everything necessary to ensure a 
proper installation before proceeding.
v
eRifying
 
The
 p
aCkage
 C
onTenTs
i
nsTallaTion
 p
lanning
Provide a platform within the cabinet upon which the oven will be 
supported. The platform must be installed level and straight. The 
top edge of the platform must be flush with the cutout at the front 
of the cabinet. There are no provisions to level the oven after it 
has been installed. 3/4” (19mm) thick plywood is recommended.
NOTE:
An oven that is not level may provide poor or inconsistent 
baking results.
i
nsTalling
 
The
 s
uppoRT
 p
laTfoRm
 
in
 
The
 
CabineT
 
 WARNING
WARNING – 
If the electrical service provided does not 
meet the product specifications, do not proceed with 
the installation. Call a licensed electrician to correct.
It is the owner’s responsibility to ensure that a qualified electrician 
performs the electrical connection of this appliance. The electrical 
installation, including minimum supply wire size, must comply with 
the National Electric Code ANSI/NFPA 70-1990* (or to the latest 
revision) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be supplied 
to the appliance from a separate, grounded, single phase circuit 
that is protected by a properly sized circuit breaker or time-delay 
fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 
and L2).
The required voltage, frequency and amperage ratings are listed 
on the product data plate (located inside the intake grill to the left 
of the door latch) and in the Table below.
The correct voltage, frequency, and amperage must be supplied 
to the appliance from a separate, grounded, single phase circuit 
that is protected by a properly sized circuit breaker or time-delay 
fuse. If a time-delay fuse is utilized, fuse both sides of the line (L1 
and L2).
The required voltage, frequency and amperage ratings are listed 
on the product name plate (located inside the intake grill to the left 
of the door latch) and in the Table below.
NOTES:
1.   Preheat times and cavity temperature recovery 
times will be increased slightly if operating on a 
120/208 volt power supply.
2.   208V models should not be connected to 240V 
source power.
3.   Power supply must be an isolated circuit.
e
leCTRiCal
 p
oweR
 s
upply
 
R
equiRemenTs