Dacor MCS130 Benutzerhandbuch

Seite von 16
7
Before attempting to connect the appliance to power, turn off the 
electrical power supply. Also, always turn off electrical power to 
the appliance prior to servicing it.
The appliance must be connected to the power supply with copper 
wire only. The use of aluminum wire may result in unsatisfactory 
connections. Flexible armored or non-metallic, sheathed copper 
cable (with grounding wire) should be used to connect the 
appliance to the junction box. A UL-listed connector must be used 
to directly connect the cable to the junction box.
Be certain to locate the junction box such that the electrical supply 
may be easily disconnected in the event that service becomes 
necessary. Also, provide extra slack in the cable to allow the oven 
to slide forward for servicing.
This appliance must be electrically grounded.
With the oven positioned directly in front of the cabinet cutout, 
feed the appliance conduit to the electrical junction box. 
Then, depending upon local codes, utilize one of the following 
techniques to connect the appliance to the electrical power 
supply:
T
uRning
 o
ff
 
The
 p
oweR
 s
upply
e
leCTRiCal
 C
onneCTion
 WARNING
WARNING – Failure to disconnect power may result in 
electrical shock or fire hazard.
 WARNING
1.  This appliance must be connected to a grounded, 
metallic, permanent wiring system. Alternatively, a 
grounding conductor should be connected to the 
grounding terminal or lead on the appliance. Failure to 
do so may result in an electrical shock hazard.
2.  Do not install a fuse in the neutral or ground circuit. A 
fuse in the neutral or ground circuit may result in an 
electrical shock hazard.
g
Rounding
 i
nsTRuCTions
i
nsTallaTion
 i
nsTRuCTions
A.  Connecting to a Four-Wire Electrical System 
1.  Separate the green and white appliance wires.
2.  Connect the white appliance wire to the neutral (white) supply wire in 
the junction box.
3.  Connect the black appliance wire to the black (L1) power supply wire 
in the junction box.
4.  Connect the red appliance wire to the red (L2) power supply wire in 
the junction box.
5.  Connect the green appliance wire to the green house grounding wire 
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Connecting the Appliance to a Four-Wire Power Supply
 WARNING
WARNING – Do not connect the green appliance wire to 
the neutral (white) junction box wire unless local building 
codes permit.
Conduit from
appliance
Cable from
power supply
Wire nut
(3 places)
Junction
box
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
Connecting the Appliance Ground to Supply Neutral
B.  Connecting the Green Appliance Wire to the Neutral 
(White) Supply  Wire – Where Local Codes Permit 
1.  Connect the green and white appliance wires to the neutral (white) 
supply wire in the junction box.
2.  Connect the black appliance wire to the black (L1) power supply wire 
in the junction box.
3.  Connect the red appliance wire to the black (L2) power supply wire in 
the junction box.