14.3  Room ventilation 
 
Caution – This cooker may only be installed and operated in rooms permanently ventilated in 
accordance with current regulations. For proper operation of a gas appliance it is essential for the 
air necessary for combustion of the gas to be able to flow naturally into the room. Air must flow 
directly into the room through openings in its outside walls. This (these) opening (s) must have a 
free passage cross-section of at least 100 cm
 
2
, or 200 cm
2
 for appliances not equipped with gas 
safety device. These openings must be constructed so that they cannot be obstructed indoors or 
outdoors, and should preferably be close to the floor on the side opposite to the combustion gas 
discharge point. If it is not possible to make the openings in the room where the cooker is installed, 
the necessary air may be taken from an adjoining room, proveded it is not a bedroom or a room 
with fire risk. 