73 
Kernel halt error messages 
 
Message 
Description 
BAD Address = nn 
Kernel memory is corrupt, hardware failure. 
Resetting to factory 
defaults 
A memory error is detected during a read 
from configuration memory. This also 
indicates a hardware failure, but the system 
may continue to initialize successfully. The 
configuration from another Unit should be 
saved to this Unit as soon as possible. 
Unit Halted 
A major error has forced the kernel to stop 
processing. The UltraMatrix waits to receive a 
kernel or main firmware file from the bottom 
board’s serial port using the serial 
parameters: 9600, N, 8, 1. Connect the serial 
cable supplied with the UltraMatrix as 
described in the Serial Port section, start a 
terminal emulator and transfer the file using 
an ASCII file transfer protocol.  
Kernel is bad, load 
new kernel through 
serial port. 
The UltraMatrix waits to receive a kernel or 
main firmware file from the bottom board’s 
serial port using the serial parameters: 9600, 
N, 8, 1. Connect the serial cable supplied 
with the UltraMatrix as described in the Serial 
Port Section, start a terminal emulator and 
transfer the file using an ASCII file transfer 
protocol.  
Checksum error 
 
The kernel writes this message at power up 
when a memory error is detected during a 
read from program memory.