Operations
Calibrate the Printer
6/30/06
105SL User Guide
11342L-001 Rev. A
Calibrate the Printer
Calibrate the printer when it is first put into service. Calibration allows the printer to establish 
the proper settings for the specific media and ribbon used in your application. You may 
calibrate the printer at other times as needed
 shows the different methods for 
calibration.
Table 7 • Types of Calibration
Type of Calibration
Description
When/How It Occurs
Auto-calibration 
The printer automatically sets the 
value it detects for the spaces 
between labels.
Occurs at the following times:
• When the printer is first turned 
on if CALIBRATION is 
selected for MEDIA POWER 
UP (see 
• When the printer feeds media 
after the printhead is closed if 
CALIBRATION is selected for 
HEAD CLOSE (see 
• As part of both the sensor 
profile and media and ribbon 
sensor calibration procedures.
Long (Standard) Calibration 
The printer does the following:
• feeds media and ribbon
• sets the values it detects for 
media length, media type 
(continuous or non-continuous), 
and print mode (thermal 
transfer or direct thermal)
• updates the sensor values
To perform a long calibration, do 
one of the following:
• Press 
PAUSE
 on the control 
panel to pause the printer, and 
then press 
CALIBRATE
.
• Select CALIBRATION for the 
MEDIA POWER UP or HEAD 
CLOSE parameter (see 
 or 
Short Calibration
The printer calibrates using the 
current sensor values rather than 
detecting the spaces between 
labels and resetting the sensors. 
This calibration sequence uses 
fewer labels than the long 
calibration sequence, but it is less 
reliable because the values that are 
stored in the sensors could be 
incorrect.
Select SHORT CAL for the 
MEDIA POWER UP or HEAD 
CLOSE parameter (see 
Sensor Profile Calibration
The printer auto-calibrates and 
prints a media sensor profile. See 
Select the SENSOR PROFILE 
option on the control panel. See 
 
for instructions.