HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Overall Description 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
22 
 
Command 
Type 
Command Format 
Description 
Note: 
If all parameters are omitted, the = symbol following <name> 
should be omitted. If <name> is not identified, this command 
does not exist. In this case, ERROR is returned. When <name> 
is identified, if a command that is not allowed to contain 
parameters contains parameters or a command that is allowed to 
contain parameters contains more parameters than the defined 
ones, "ERROR" or 
“+CME ERROR : operation not allowed” is 
returned. 
Read 
command 
<name>? 
A read command is 
executed to read the 
current value of a 
parameter.   
test 
command 
<name>=? 
A test command is 
executed to check the 
parameter range.   
Note: 
If the MS fails to identify <name>, the MT returns ERROR. If the 
MT can identify <name> and the contents returned by the 
command do not contain parameters, the MS returns OK. If the 
contents returned by the command contain parameters, the MS 
returns the value range of each parameter, and then returns OK.   
 
1.4.3 Abort Attributes of AT Commands 
Abort means that the TE sends an instruction to abort a command when the 
command is being executed. An abort instruction must be sent before a command is 
completely executed. Therefore, the abort instruction is valid for a command whose 
execution consumes certain time; however, not all commands of this kind can be 
aborted. Whether a command can be aborted depends on the abort attribute of the 
command. Each AT command has its abort attribute, which is alternative. That is, the 
command is either abortive or not abortive. Abortive commands include certain basic 
commands and execution commands of action commands. Within 125 ms after the 
abortive commands are sent, no abort request is accepted. After 125 ms and before 
the commands are completely executed, if the module receives any character sent 
by the TE, the commands are aborted immediately. 
1.4.4 Rules for Running AT Commands 
1.  Each  command  line  contains  only  one  AT  command  and  ends  with  a  carriage 
return  character,  in  addition  to  the  basic  standard  commands  such  as  1,  V,  S3 
etc.  In  principle,  users  are  not  allowed  to  run  S3/S4  format  modification 
commands.  This  rule  is  applicable  to  the  communication  between  the  MT  and 
TE programs. 
2.  To increase the readability and regularity of command and response formats, in 
addition  to  the  original  interfaces  specified  in  standards  and  protocols,  all  new 
interfaces  must  observe  the  following  rule:  No  space  is  added  to  the  end  of 
commands  such  as  the  AT^XXX=<arg0>,<arg1>  commands,  or  added  to  the 
end of the ^ symbol, colon, and comma. No redundant space is added ahead of