MAINTENANCE
14) Unplug the green (TH) and white (TP/TH) 
wires from the valve.
15) Disconnect the 2 DC Spark generator wires 
from the DC spark box located in front of 
the valve.
16) Disconnect the spark electrode wire from  
the DC spark box.
DC Spark Box
DC Spark Box
17) Remove the 16 screws that hold the valve 
tray to the fi rebox and slightly pull out the 
valve tray.
Valve Tray
MAINTENANCE
18) Completely pull out the valve tray.
19) Replace the valve tray and reverse steps 
to re-install.
20) Turn on the gas supply and check for gas  
leaks.
21) Re-install the rear log stand.
22) Re-install the burner tube.
23) Re-install the grate.
24) Re-install the brick panels.
25) Re-install the burner ofi rice cover plate. 
26) Re-install the log set.
27) Re-install the glass door.
28) Re-install the front cover plate
29) Re-install the mesh screen.
30) Check the inlet and outlet pressures.
31) Check operation of fl ame control.
32) Check for proper fl ame appearance.
11) Disconnect the inlet gas line from the  
valve.
12) Undo the center wire clip on the side of the 
fi rebox.
13)  Unplug the wire harness that connects the 
modulating coil to the receiver.