Chapter 3:  Installation 
32 
Connecting Filter Chambers 
Make sure that all previous installation steps have been done first before starting this task. 
You’ll use one yellow patch cord to connect. 
To connect a filter chamber to the network: 
1.  Attach one connector of the yellow patch cord to the terminal on the filter chamber 
terminal box. Tighten the cord grip ring until snug. 
Figure 15:  Proper Filter Chamber Connections 
VFC Filter Chamber
Grey Network Flat Cable
Black Power Flat Cable
Vacuum Tube
ArmorBlock Mounting Plate Kit
Part No. A0556696
8 Input / 8 Output ArmorBlock
Part No. A0555192
ArmorBlock Base
Part No. A0555191
Yellow Patch Cord, 20 ft. (6 m)
Part No. A0555190
 
 
2.  Attach the other connector to the lower right terminal of the ArmorBlock you used 
to connect the vacuum pump. Tighten the cord grip ring until snug. 
Note:  Retain the terminal caps from the ArmorBlock. They may be used 
later. 
3.  Dress the excess patch cord cables with cable ties so they do not interfere with 
operation and to give a pleasing appearance.