O P E R A T I O N
Options Window
350-9047 v3.0.1
DGy Model 201x User’s Guide
56
. . . . .
warning message is displayed asking to reboot 
immediately. If the DGy is rebooted, the WCP or Telnet 
session must be reactivated.
C L O C K   S Y N C H R O N I Z A T I O N
The DGy 201x internal real time clock can be synchronized to 
an external time reference so that it is always set accurately. 
Accurate time references are provided by conventional Network 
Time Servers (NTS) over the internet using the Network Time 
Protocol (NTP). Alternatively an optional IRIG-B time reference 
can be used. The Clock synchronization section provides the 
ability to set operation with either type of external time 
reference.
Radio buttons are provided to set the DGy 201x’s timecode 
synchronization functions, including NTS and IRIG (IRIG-B is an 
optional DGy 201x feature) assignments. 
NTS Time Synchronization
~
At least one IP address must be in the NTS List before 
the 
Network Time Server
 radio button can be selected. 
Up to three IP addresses can be set. Be sure that the 
DGy 201x can access the time server over the network 
connection. In Chapter 6, refer to the 
 command description for details.
~
To put an entry into the NTS list box, click on the 
Edit
 
button associated with the NTS list.
~
Enter the new server IP address and press 
ENTER
~
To change an existing entry, first select the desired 
device using the drop down 
NTS
 list box. Click on the 
Edit
 button. Enter the new server IP address into the 
NTS
 list box and press 
ENTER
.
~
Click the 
Network Time Server
 radio button to activate 
NTS synchronization.
OR
IRIG-B Time Synchronization
~
If the IRIG option is installed, the 
IRIG Standard
 must be 
selected before the IRIG radio button can be selected. 
Select the required input type, DCLS or 1kHz 
modulated, using the drop down menu.
~
In the 
Clock Synchronization
 section click the 
IRIG
 radio 
button to activate IRIG synchronization.